The DOI matches its Crossref record; the references it cites are not checked yet.
Thoracic Endovascular Repair (TEVAR) for Blunt Traumatic Thoracic Aortic Injury: Long-Term Results.
Abstract
Background:Blunt traumatic thoracic aortic injury (TAI) is a critical injury with high mortality and an uncertain prognosis. In the last twenty years, thoracic endovascular repair (TEVAR) has become the treatment of choice compared to surgery, as it reduces mortality and morbidity. To date, a few studies evaluated long-term clinical and radiological follow-up of TEVAR for blunt traumatic TAI. The main concerns related to long-term follow-up relate to late endograft-related complications, morphological changes in the aorta and the consequences of life-long surveillance in terms of cumulative radiation dose.Results:Technical success was achieved in 38 procedures (100%). The TEVAR-related mortality rate was 0%. No immediate major complications related to the endovascular procedure were observed. The median duration of diagnostic follow-up was 80 months. A total of 4 procedure-related complications (10.5%) were identified at the follow-up. Three (7.9%) distal infoldings and collapses of the thoracic endoprosthesis and one (2.6%) type Ia endoleak were observed. No thrombosis of the prosthesis, nor signs of aortic pseudocoarctation were identified. No further complications related to endograft (endoleaks, infections, rupture, partial or complete thrombosis) occurred. No changes in the native aorta, stenosis, or increases in the endograft’s diameters were observed. A total of 20 patients (52.6%) underwent MRI-angiography examinations, while a total of 34 patients (89.5%) underwent chest radiographs at the follow-up. In all cases, CT-angiography examinations were performed at the follow-up.Conclusions:The consequences of lifelong surveillance deserve special consideration in younger patients treated with thoracic endovascular repair (TEVAR) for blunt traumatic thoracic aortic injury (TAI). Procedure-related complications were observed within one year of TEVAR, limiting concerns related to the durability of the prosthesis. No morphological changes in the aorta were observed despite long-term follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Arterial introducer sheaths ranging in size from 4 to 8 Fr are used in most interventional radiology procedures [1,2,3,4,5,6,7,8,9,10,11,12].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 7
Metadata
- Authors
- Minici, R., Serra, R., Ierardi, A. M., Petullà, M., Bracale, U. M., Carrafiello, G., & Laganà, D.
- Publisher
- Research Square Platform LLC
- Published
- 2022-03-24
- Cited by
- 7
- Type
- Preprint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thoracic Endovascular Repair (TEVAR) for Blunt Traumatic Thoracic Aortic Injury: Long-Term Results. https://app.cochat.ai/papers/10.21203/rs.3.rs-1450003/v1
- The paper
- Minici, R., Serra, R., Ierardi, A. M., Petullà, M., Bracale, U. M., Carrafiello, G., & Laganà, D. (2022). Thoracic Endovascular Repair (TEVAR) for Blunt Traumatic Thoracic Aortic Injury: Long-Term Results. https://doi.org/10.21203/rs.3.rs-1450003/v1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.