Cited by 1Cardiac Arrhythmias and TreatmentsCardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmias

Magnetic Versus Manual Catheter Navigation for Ablation of Ventricular Tachycardia: A Systemic Review and Meta-Analysis

Open access
Division of Cardiology, Cardiac Arrhythmia Service, Medical College of Wisconsin, Milwaukee, United States, Garg, Jalaj, Gupta, Rajiv, Chaudhary, Rahul, Department of Medicine, Mayo Clinic School of Medicine, Rochester, United States, Gupta, Rahul, Department of Medicine, Westchester Medical Center, Valhalla, United States, Patel, Roshni N +5 more·2019·Asian Journal of Medical Research

Abstract

Background: This study was conducted to evaluate the efficacy, and procedural complications of remote magnetic navigation (RMN) versus manual catheter navigation (MCN) for ablation of ventricular tachycardia.Subjects and Methods: We performed electronic searches on PubMed, The Cochrane Library, EMBASE, EBSCO, Web of Science and CINAHL databases from inception through April 6, 2017, to identify clinical trials comparing RMN with MCN.The primary efficacy outcomes were acute failed ablation and recurrent VT rates.Secondary outcomes in our study were procedural time, fluoroscopic time and procedural complications.Results: Six clinical trials, including a total of 582 patients, were identified, of which 324 underwent RMN guided VT ablation, and 258 underwent MCN guided VT ablation.Acute procedural success (or reduced failed VT ablation rates) was significantly improved with RMN group versus MCN group (10% versus 19% respectively, RR 0.56; 95% CI 0.38 -0.83) with no statistically significant difference in the recurrent VT rates (RR 0.87, 95% CI 0.64-1.19).The total procedure time was not significantly different between the two groups.However, the total fluoroscopy time (Standard mean difference -1.00, 95% CI -1.32 --0.67; p<0.001) was significantly lower and a trend towards reduced procedural complications (RR 0.40, 95% CI 0.16 -0.99; p=0.05) was observed in the RMN group versus MCN group, respectively.Conclusion: In this meta-analysis, there was a significant benefit regarding acute VT ablation success rate and a significant reduction in radiation exposure, with a trend towards reduction in procedure-related complication in patients undergoing RMN guided VT ablation versus MCN VT ablation approach.

Integrity signals

Registry

Crossref · 10.21276/ajmr.2019.8.4.me1

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Division of Cardiology, C. A. S., Garg, J., Gupta, R., Chaudhary, R., Department of Medicine, M. C. S. O. M., Gupta, R., Department of Medicine, W. M. C., Patel, R. N., Muhlenberg College, A., Turagam, M., Helmsley Centre for Cardiac Electrophysiology, I. S. O. M. A. M. S., Neki, N. S., & Professor, D. O. M.
Venue
Asian Journal of Medical Research
Published
2019-12
Volume
8
Issue
4
Pages
ME01-ME06
ISSN
  • 2277-7253 (ISSN-L)
  • 2347-3398
OpenAlex
W3027851923
Cited by
1
References
0
Citations by year
2026: 1
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
Asian Journal of Medical Research (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
ventricular tachycardia, catheter navigation, magnetic navigation, catheter ablation, procedural success, procedural complications

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review