The DOI matches its Crossref record.
Particle Size Analysis by Hydrometer: A Simplified Method for Routine Textural Analysis and a Sensitivity Test of Measurement Parameters
Abstract
A simple modification of the Day (1965) hydrometer method is suggested for routine textural analysis. The simplified method requires no calibration, graphs or tables and uses a weighted average of the 1.5‐hour and 24‐hour readings to determine the 2µm clay fraction. The relationship is: urn:x-wiley:03615995:saj2sssaj197903615995004300050038x:equation:saj2sssaj197903615995004300050038x-math-0001 where P 2µm = summation percentage for the 2µm clay fraction. P 24 , P 1.5 = summation percentage for settling time of 24 hour and 1.5 hour, respectively. K = weighting factor, used to approximate the actual relation of the summation percentage curve over the clay percentage range of interest. This equation was found to be satisfactory in the range of 5% ⩽ P 2µm ⩽60% by weight for over 70 North Dakota soil and subsoil materials when K =0.876. Sensitivity analyses were performed for the Day, Bouyoucos, and the Simplified Day hydrometer methods to determine which of several measured parameters contribute to the greatest possible error; hence which parameters should be controlled with the greatest precision. The hydrometer scale reading error contributes more error than any other single parameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gee, G. W., & Bauder, J. W. (1986) · SSSA Book Series · doi:10.2136/sssabookser5.1.2ed.c15 · Cited by 8,807
Self-citationGee, G. W., & Or, D. (2002) · SSSA Book Series · doi:10.2136/sssabookser5.4.c12 · Cited by 964
Self-citationCritical Evaluation of the Use of Laser Diffraction for Particle-Size Distribution Analysis
Eshel, G., Levy, G. J., Mingelgrin, U., & Singer, M. J. (2004) · Soil Science Society of America Journal · doi:10.2136/sssaj2004.0736 · Cited by 609
Jangid, K., Williams, M. A., Franzluebbers, A. J., Sanderlin, J. S., Reeves, J. H., Jenkins, M. B., Endale, D. M., Coleman, D. C., & Whitman, W. B. (2008) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2008.07.030 · Cited by 577
A Field Evaluation of Rain Garden Flow and Pollutant Treatment
Dietz, M. E., & Clausen, J. C. (2005) · Water, Air, and Soil Pollution · doi:10.1007/s11270-005-8266-8 · Cited by 402
Metadata
- Authors
- Gee, G. W., & Bauder, J. W.
- Venue
- Soil Science Society of America Journal
- Publisher
- Wiley
- Published
- 1979-09
- Volume
- 43
- Issue
- 5
- Pages
- 1004-1007
- ISSN
- 0361-5995 (ISSN-L)
- 1435-0661
- OpenAlex
- W1998043318
- Cited by
- 470
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Particle Size Analysis by Hydrometer: A Simplified Method for Routine Textural Analysis and a Sensitivity Test of Measurement Parameters. https://app.cochat.ai/papers/10.2136/sssaj1979.03615995004300050038x
- The paper
- Gee, G. W., & Bauder, J. W. (1979). Particle Size Analysis by Hydrometer: A Simplified Method for Routine Textural Analysis and a Sensitivity Test of Measurement Parameters. Soil Science Society of America Journal. https://doi.org/10.2136/sssaj1979.03615995004300050038x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.