Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Standardizing Characterization of Electromagnetic Water Content Sensors: Part 1. Methodology

Open access
Jones, S. B., Blonquist, J. M., Robinson, D. A., Rasmussen, V. Philip, Or, D. · 2005 · Vadose Zone Journal

Abstract

Performance differences in the growing number of electromagnetic (EM) sensors designed to estimate soil water content from a variety of indirect measurements (e.g., from measured travel time, capacitance, frequency shift) suggests the need for a standardized sensor characterization methodology. We suggest that characterization and evaluation of EM sensors, which currently lack citable standards, be performed in a homogeneous fluid of known permittivity rather than in a porous medium of unknown permittivity. Our objectives were to (i) develop a methodology for evaluating EM sensor measurement attributes referencing sensor‐specific characteristics and targeted soil properties and (ii) suggest standards for characterization and comparison of sensors. Criteria for qualitative assessment of sensors include determination of effective measurement frequency; susceptibility to variations in salinity, dielectric relaxation, and temperature; and a look at spatial variation in sensor sampling area. Measurement frequencies for broadband sensors can be inferred from correlated network analyzer and sensor measurements or from manufacturer suggestions. Fluids were selected to provide surrogate soil‐related effects such as relaxation occurring both within and outside of the effective measurement frequency range of common sensors. Test conditions included dielectrically relaxing (R) and nonrelaxing (NR) as well as electrically conducting (C) and nonconducting (NC) liquids and combinations thereof (e.g., NR‐C). No suitable combination of relaxing and conducting (R‐C) dielectric fluid was found in this study, but this remains a goal of future work because it represents a difficult and often common condition for EM sensor measurements in soils containing contributors to relaxation (e.g., clays, organic matter). Standards are based on fluids of known (based on Cole–Cole parameters) or measurable (using a network analyzer) frequency dependent permittivity that provide a reproducible homogeneous system for immersion of EM sensors. The methodology described here was applied using seven different EM sensing systems, and results are given in a companion paper.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2136/vzj2004.0140

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 178

Metadata

Authors
Jones, S. B., Blonquist, J. M., Robinson, D. A., Rasmussen, V. P., & Or, D.
Venue
Vadose Zone Journal
Publisher
Wiley
Published
2005-11
Volume
4
Issue
4
Pages
1048-1058
ISSN
1539-1663 (ISSN-L)
OpenAlex
W2144442651
Cited by
178
References
2
FWCI
23.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.