The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
XANES calibrations for the oxidation state of iron in a silicate glass
Abstract
Fe K-edge X-ray absorption near edge structure (XANES) spectra were recorded for a series of anorthite-diopside eutectic glasses containing 1 wt% 57 Fe 2 O 3 quenched from melts equilibrated over a range of oxygen fugacities at 1409 °C. The Fe 3+ /ΣFe ratios were determined previously by 57 Fe Mössbauer spectroscopy and vary between 0 (fully reduced) and 1 (fully oxidized). Using the Mössbauer results as a reference, various methods for extracting Fe 3+ /ΣFe ratios from XANES spectra were investigated. The energy of the 1s → 3d pre-edge transition centroid was found to correlate linearly with the oxidation state. Correlations also exist with the energy of the K absorption edge and the area of peaks in the derivative spectrum associated with the 1s → 4s and crest (1s → 4p) transitions. The Fe 3+ /ΣFe ratios determined from linear combinations of end-member spectra (Fe 3+ /ΣFe ~0 and ~1) were found to deviate significantly from the Mössbauer values. This may indicate the susceptibility of this method either to errors arising from the treatment of the background or to changes in Fe 2+ or Fe 3+ coordination with the Fe 3+ /ΣFe ratio. The general applicability of any XANES calibration for determining oxidation states is limited by variations in the Fe coordination environment, which affects both the intensity and energy of spectral features. Thus previous calibrations based on mineral spectra are not applicable to silicate glasses. Nevertheless, systematic trends in spectral features suggest that Fe 3+ /ΣFe values may be obtained from XANES spectra, with an accuracy comparable to Mössbauer spectroscopy, by reference to empirical calibration curves derived from compositionally similar standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multiplet Analysis of Fe K-Edge 1s → 3d Pre-Edge Features of Iron Complexes
Westre, T. E., Kennepohl, P., DeWitt, J. G., Hedman, B., Hodgson, K. O., & Solomon, E. I. (1997) · Journal of the American Chemical Society · doi:10.1021/ja964352a · Cited by 1,473
Oxidation state and coordination of Fe in minerals: An Fe K-XANES spectroscopic study
Wilke, M., Farges, F., Petit, P.-E., Brown, G. E., & Martin, F. (2001) · American Mineralogist · doi:10.2138/am-2001-5-612 · Cited by 1,118
K-edge absorption spectra of selected vanadium compounds
Wong, J., Lytle, F. W., Messmer, R. P., & Maylotte, D. H. (1984) · Physical Review B · doi:10.1103/physrevb.30.5596 · Cited by 1,078
The redox states of basic and silicic magmas: a reflection of their source regions?
Carmichael, I. S. E. (1991) · Contributions to Mineralogy and Petrology · doi:10.1007/bf00306429 · Cited by 652
Role of oxygen pressure in the crystallization and differentiation of basaltic magma
Osborn, E. F. (1959) · American Journal of Science · doi:10.2475/ajs.257.9.609 · Cited by 535
Ferric-ferrous equilibria in natural silicate liquids at 1 bar
Sack, R. O., Carmichael, I. S. E., Rivers, M., & Ghiorso, M. S. (1981) · Contributions to Mineralogy and Petrology · doi:10.1007/bf00374720 · Cited by 431
Light transmission in quasiperiodic multilayers of porous silicon
Nava, R., Agarwal, V., del Rı&#x;o, J. A., & Wang, C. (2003) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2003.08.028 · Cited by 426
Farges, F., Brown, G. E., & Rehr, J. J. (1996) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(96)00144-5 · Cited by 329
X-ray K-edge absorption spectra of Fe minerals and model compounds: Near-edge structure
Waychunas, G. A., Apted, M. J., & Brown, G. E. (1983) · Physics and Chemistry of Minerals · doi:10.1007/bf01204319 · Cited by 322
O'Neill, H. S. C., & Eggins, S. M. (2002) · Chemical Geology · doi:10.1016/s0009-2541(01)00414-4 · Cited by 321
Self-citation
Cited by
The oxidation state of Fe in MORB glasses and the oxygen fugacity of the upper mantle
Cottrell, E., & Kelley, K. A. (2011) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2011.03.014 · Cited by 473
Determination of Mn valence states in mixed-valent manganates by XANES spectroscopy
Manceau, A., Marcus, M. A., & Grangeon, S. (2012) · American Mineralogist · doi:10.2138/am.2012.3903 · Cited by 351
Pollastri, S., D’Acapito, F., Trapananti, A., Colantoni, I., Andreozzi, G. B., & Gualtieri, A. F. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.05.010 · Cited by 51
Metadata
- Authors
- Berry, A. J., O’Neill, H. S. C., Jayasuriya, K. D., Campbell, S. J., & Foran, G. J.
- Venue
- American Mineralogist
- Publisher
- Mineralogical Society of America
- Published
- 2003-07
- Volume
- 88
- Issue
- 7
- Pages
- 967-977
- ISSN
- 0003-004X (ISSN-L)
- OpenAlex
- W2215717315
- Cited by
- 313
- References
- 20
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: XANES calibrations for the oxidation state of iron in a silicate glass. https://app.cochat.ai/papers/10.2138/am-2003-0704
- The paper
- Berry, A. J., O’Neill, H. S. C., Jayasuriya, K. D., Campbell, S. J., & Foran, G. J. (2003). XANES calibrations for the oxidation state of iron in a silicate glass. American Mineralogist. https://doi.org/10.2138/am-2003-0704
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.