Experimental determination of siderite stability and application to Martian Meteorite ALH84001
Abstract
The pressure-temperature equilibrium curve of the reaction siderite + hematite = magnetite + CO 2 was determined in the range 5-12 kbar and 480-650 °C by piston-cylinder experiments, with NaCl as a pressure medium. Silver oxalate was used as a CO 2 source and samples were buffered at hematitemagnetite oxygen fugacity. Reaction progress was monitored by extent of CO 2 gas loss and by X-ray diffraction (XRD) analysis. The data define a univariant curve, which is described by P = -14.599 + 0.025T + 0.000027 T 2 with P in kbar and T in °C. Calculations based on these data give ΔH 0 f (298K) siderite = -760.6 ± 0.9 kJ (kilojoules) from the oxides. The formation of siderite requires a specific range of ambient oxygen and carbon dioxide fugacities, dependent upon temperature and pressure. The stable assemblage of siderite and magnetite, at a given temperature and pressure, implies more restrictive ranges of oxygen and carbon dioxide fugacities, defined by reactions among siderite, magnetite, graphite, and hematite. Experimental and thermodynamic investigation of the Fe-C-O system indicates that the formation of magnetite along with Ca-Fe-Mg carbonate globules by inorganic processes is possible and may be relevant to Martian meteorite ALH84001. Decarbonation of the siderite component of the carbonate, either by a transient heating event or by a change in oxygen fugacity of a coexisting fluid, may have formed the observed grains, although this study does not address the size or morphology of magnetite grains formed by this mechanism.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As the temperature decreases from 400 °C to 0 °C, fO2 decreases in a system buffered by hematite and magnetite.
“However, as the temperature decreases from 400 °C to 0 °C, so does fO 2 in a system buffered by hematite and magnetite.”
From Comprehensive imaging and Raman spectroscopy of carbonate globules from Martian meteorite ALH 84001 and a terrestrial analogue from Svalbard (2007) · cites this paper as Koziol 2004
Cited by
Sorted by citations
Steele, A., Fries, M. D., Amundsen, H. E. F., Mysen, B. O., Fogel, M. L., Schweizer, M., & Boctor, N. Z. (2007) · Meteoritics & Planetary Science · doi:10.1111/j.1945-5100.2007.tb00590.x · Cited by 117 · see citing works
BELL, M. S. (2007) · Meteoritics & Planetary Science · doi:10.1111/j.1945-5100.2007.tb01142.x · Cited by 53 · see citing works
- Authors
- Koziol, A. M.
- Affiliations
- University of Dayton (US)
- Corresponding author
- Koziol, Andrea M.
- Venue
- American Mineralogist
- Publisher
- Mineralogical Society of America
- Published
- 2004-02
- Volume
- 89
- Issue
- 2-3
- Pages
- 294-300
- ISSN
- 0003-004X (ISSN-L)
- OpenAlex
- W2309178612
- Cited by
- 38
- References
- 0
- Citations by year
- 2025: 1 · 2024: 2 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 2 · 2017: 1 · 2016: 3 · 2015: 2 · 2014: 3 · 2013: 2 · 2012: 3
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Mineralogist (publishedVersion)
- Funders
- National Science Foundation
- University of Dayton
- Topics
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geological and Geochemical Analysis
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Planetary Science and Exploration
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Astro and Planetary Science
- Keywords
- oxygen fugacity, fugacity of CO2, decarbonation, carbonate globules, magnetite, piston-cylinder experiments
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review