Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 240

The DOI matches its Crossref record.

Analytical perils (and progress) in electron microprobe trace element analysis applied to geochronology: Background acquisition, interferences, and beam irradiation effects

Jercinovic, M. J. · 2005 · American Mineralogist

Abstract

Electron probe microanalysis (EPMA) of accessory minerals such as monazite, xenotime, and thorite for minor- and trace-element concentrations and geochronology, requires consideration of beam irradiation effects (increasing heat and charge) as higher current densities and lengthy counting times are employed, and requires careful, detailed assessment of background intensities and interferences. A carbon coat (250 Å thickness) is generally inadequate for prevention of absorbed current fluctuation and beam damage when using the high current densities applied for high precision (e.g., 200 nA, focused beam). Beam irradiation effects include element mobility in monazite, resulting in P loss relative to REE. Coating materials of higher electrical and thermal conductivity are indicated, and use of gold (≥100 Å) is strongly suggested. Systematic compositional and, therefore, age variability can result simply from analytical effects, requiring evaluation of all aspects of data acquisition. The spectra relevant to measurement of Y, Th, Pb, and U are complex, especially in REE-bearing minerals. Acquisition of detailed spectral wavelength scans allows recognition of background and peak interferences, as well as curvature. Background intensities can be extracted directly from scan data by regression. X-ray mapping allows delineation of domains, guiding background acquisition and detailed quantitative analysis. Minor substitution or fluorescence of unexpected elements can compromise analyses, one documented effect being the fluorescence of K in monazite adjacent to, or hosted by, K-feldspar or micas. This effect, clearly evident within 10 micrometers from K-feldspar, can result in erroneous U concentrations leading to misinterpretation of rim .ages. as younger overgrowths. Absorption edges associated with Th also become relevant to the measurement of U at high Th concentrations. Because background intensity is sensitive to variation in average atomic number, backgrounds must be acquired from each identified domain, with particular attention being paid to Th variation. Misapplication of background intensities can result in large age discrepancies, for example, application of backgrounds obtained from a high-Th domain in monazite to measurement of a low-Th domain (1/3 of the amount in the high-Th domain) results in an overestimation of the UMβ background intensity of 0.008 cps/nA, and an overall “increase” in age of 70 m.y.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2138/am.2005.1422

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 240

Metadata

Authors
Jercinovic, M. J.
Venue
American Mineralogist
Published
2005-04-01
Volume
90
Issue
4
Pages
526-546
ISSN
0003-004X (ISSN-L)
OpenAlex
W2065217542
Cited by
240
References
0
FWCI
19.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analytical perils (and progress) in electron microprobe trace element analysis applied to geochronology: Background acquisition, interferences, and beam irradiation effects. https://app.cochat.ai/papers/10.2138/am.2005.1422
The paper
Jercinovic, M. J. (2005). Analytical perils (and progress) in electron microprobe trace element analysis applied to geochronology: Background acquisition, interferences, and beam irradiation effects. American Mineralogist. https://doi.org/10.2138/am.2005.1422

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.