The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Improved Real-Time RT-PCR Method for High-Throughput Measurements using Second Derivative Calculation and Double Correction
Open accessAbstract
Quantification of mRNA expression levels using real-time reverse transcription PCR (RT-PCR) is increasingly used to validate results of DNA microarrays or GeneChips. It requires an improved method that is more robust and more suitable for high-throughput measurements. In this report, we compare a user non-influent, second derivative method with that of a user influent, fit point method that is widely used in the literature. We also describe the advantage of using a double correction: one correction using the expression levels of a housekeeping gene of an experiment as an internal standard and a second using reference expression levels of the same housekeeping gene in the tissue or cells. The first correction permits one to decrease errors due to sample preparation and handling, while the second correction permits one to avoid the variation of the results with the variability of housekeeping in each tissue, especially in experiments using various treatments. The data indicate that the real-time PCR method is highly efficient with an efficiency coefficient close to the theoretical value of two. The results also show that the second derivative method is more accurate than the fit point method in quantifying low gene expression levels. Using triplicate experiments, we show that measurement variations using our method are low with a mean of variation coefficients of <1%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Der, S. D., Zhou, A., Williams, B. R. G., & Silverman, R. H. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15623 · Cited by 1,816
Livak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Genome-wide expression monitoring in Saccharomyces cerevisiae
Wodicka, L., Dong, H., Mittmann, M., Ho, M.-H., & Lockhart, D. J. (1997) · Nature Biotechnology · doi:10.1038/nbt1297-1359 · Cited by 973
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
Cited by
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Schefe, J. H., Lehmann, K. E., Buschmann, I. R., Unger, T., & Funke-Kaiser, H. (2006) · Journal of Molecular Medicine · doi:10.1007/s00109-006-0097-6 · Cited by 859
Valasek, M. A., & Repa, J. J. (2005) · Advances in Physiology Education · doi:10.1152/advan.00019.2005 · Cited by 574
Transcriptomic and metabolite analyses of Cabernet Sauvignon grape berry development
Deluc, L. G., Grimplet, J., Wheatley, M. D., Tillett, R. L., Quilici, D. R., Osborne, C., Schooley, D. A., Schlauch, K. A., Cushman, J. C., & Cramer, G. R. (2007) · BMC Genomics · doi:10.1186/1471-2164-8-429 · Cited by 462
Wang, Z., Mascarenhas, N., Eckmann, L., Miyamoto, Y., Sun, X., Kawakami, T., & Di Nardo, A. (2017) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2016.09.019 · Cited by 117
Metadata
- Authors
- Luu-The, V., Paquet, N., Calvo, E., & Cumps, J.
- Venue
- BioTechniques
- Publisher
- Informa UK Limited
- Published
- 2005-02
- Volume
- 38
- Issue
- 2
- Pages
- 287-293
- ISSN
- 0736-6205 (ISSN-L)
- 1940-9818
- OpenAlex
- W2131360646
- Cited by
- 284
- References
- 21
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Real-Time RT-PCR Method for High-Throughput Measurements using Second Derivative Calculation and Double Correction. https://app.cochat.ai/papers/10.2144/05382rr05
- The paper
- Luu-The, V., Paquet, N., Calvo, E., & Cumps, J. (2005). Improved Real-Time RT-PCR Method for High-Throughput Measurements using Second Derivative Calculation and Double Correction. BioTechniques. https://doi.org/10.2144/05382rr05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.