CoChat

Detection of Protease Activity Using a Fluorescence-Enhancement Globular Substrate

Open access
Voss, Edward W., Workman, Creg J., Mummert, Mark E. · 1996 · BioTechniques
Cited by 72

The DOI matches its Crossref record.

Abstract

Bovine serum albumin (BSA) highly derivatized with fluorescein isothiocyanate (FITC, isomer I) served as a fluorescent enhancement substrate to measure protease activity. In the native globular BSA structure, the fluorescence of the lysine-conjugated fluorescein moieties was quenched 98%. Proteolytic digestion of highly derivatized BSA with Pronase resulted in fluorescence enhancement of 4300%. Both alpha-chymotrypsin and proteinase K yielded lower but similar fluorescence enhancement values of 2880% and 2800%, respectively. Digestion of the fluorescein-BSA substrate with trypsin, which required basic amino acids for activity, showed fluorescence enhancement of 1480% reflecting the fluorescein-lysine thiocarbamyl linkage. When derivatized substrate was pretreated with a thiol-reducing agent prior to incubation with proteases, a relatively small increase in fluorescence was noted relative to the untreated substrate except in the case of Pronase. The minimum sensitivity of proteolytic activity, based on a comparison of untreated and reduced FITC25BSA was 32 x 10(-6) units for I ng proteinase K, 1 x 10(-3) units for 1 ng alpha-chymotrypsin and 10 x 10(-3) units for Pronase and trypsin (1 ng each). The fluorescence enhancement assay was suited for sensitive intensity measurements or as an endpoint assay to detect protease activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2144/96202rr06

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Voss, E. W., Workman, C. J., & Mummert, M. E.
Venue
BioTechniques
Published
1996-02
Volume
20
Issue
2
Pages
286-291
ISSN
  • 0736-6205 (ISSN-L)
  • 1940-9818
OpenAlex
W2181548009
Cited by
72
References
0
FWCI
2.43
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.