CoChat

Modified Hirt Procedure for Rapid Purification of Extrachromosomal DNA from Mammalian Cells

Open access
Arad, Uri · 1998 · BioTechniques
Cited by 105

The DOI matches its Crossref record.

Abstract

Methods for extracting extrachromosomal DNA from eukaryotic cells are important for many studies such as DNA replication and identification of certain viruses (2). The procedure described by Hirt (4), which has been widely used over the last thirty years, is laborious and time-consuming and requires phenol extraction. More rapid methods using anion-exchange chromatography (5) or silicon-based resins (3) use the alkaline lysis procedure that was originally developed for extracting plasmid DNA from bacterial cells (1). Only covalently closed circular DNA renatures correctly and stays in solution on rapid neutralization of the alkaline lysis buffer, whereas linear and open circular DNA precipitate together with the denatured proteins and chromosomal DNA (3). Thus, certain DNA replication intermediates are not recovered. This report describes a modification in which lysis at neutral pH, as in the Hirt procedure, combined with purification on a silica-gel membrane, enables the rapid recovery of linear and relaxed circular DNA along with the supercoiled form. Cells (106–107) are dispersed with trypsin, pelleted and washed in Ca2+/ Mg2+-free phosphate-buffered saline (PBS). They are resuspended in 250 μL 50 mM Tris-HCl, pH 7.5, 10 mM EDTA containing 100 μg/mL RNase A and lysed by the addition of 250 μL 1.2% sodium dodecyl sulfate (SDS). The suspension is gently mixed by inverting the tube several times and then stands for 5 min at ambient temperature. Adherent cells can be lysed directly in the culture plate after washing with PBS by overlaying them with 500 μL of a mixture of equal volumes of the above resuspension and lysis solutions. The plates are gently agitated to completely cover all cells, and the lysate is subsequently transferred to 1.5-mL microcentrifuge tubes. Cellular debris and chromosomal DNA are precipitated by the addition of 350 μL 3 M CsCl, 1 M potassium acetate and 0.67 M acetic acid. The tubes are immediately but gently mixed and placed on ice for 15 min. After centrifugation for 15 min at 14 000× g, the supernatant is loaded onto a silica gel membrane column (QIAprep Spin Column; Qiagen GmbH, Hilden, Germany). The column is washed with 750 μL 80 mM potassium acetate, 10 mM Tris-HCl, pH 7.5, 40 μM EDTA and 60% ethanol. DNA is then eluted with 50 μL water or TE buffer (10 mM Tris-HCl, pH 8.0, 1 mM EDTA). These columns are loaded, washed and eluted by centrifugation at 14 000× g or vacuum. COS cells were transfected with pSL3-EGFP, an 8.0-kb plasmid that contains the simian virus 40 (SV40) origin of replication. Twenty-four hours posttransfection, cells were suspended

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2144/98245bm14

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 105

Metadata

Authors
Arad, U.
Venue
BioTechniques
Published
1998-05
Volume
24
Issue
5
Pages
760-762
ISSN
  • 0736-6205 (ISSN-L)
  • 1940-9818
OpenAlex
W39050333
Cited by
105
References
0
FWCI
1.01
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modified Hirt Procedure for Rapid Purification of Extrachromosomal DNA from Mammalian Cells. https://app.cochat.ai/papers/10.2144/98245bm14
The paper
Arad, U. (1998). Modified Hirt Procedure for Rapid Purification of Extrachromosomal DNA from Mammalian Cells. BioTechniques. https://doi.org/10.2144/98245bm14

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.