Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Chronic central serous chorioretinopathy: long-term follow-up and vision-related quality of life

Open access
Breukink, Myrte B, Dingemans, Alexander JM, den Hollander, Anneke I, Keunen, Jan EE, MacLaren, Robert E, Fauser, Sascha, Querques, Giuseppe, Hoyng, Carel B, Downes, Susan M, Boon, Camiel JF · 2016 · Clinical Ophthalmology

Abstract

Purpose: To describe the clinical findings and long-term outcome of patients with chronic central serous chorioretinopathy (cCSC). Materials and methods: This was a retrospective case series in 52 eyes of 36 patients with a follow-up period of at least 1 year. Extensive ophthalmic examination and a validated questionnaire concerning vision-related quality of life (National Eye Institute Visual Function Questionnaire [NEI-VFQ]-39) were analyzed. Results: Mean visual acuity showed a significant decline over time of 0.16 logarithm of minimum angle of resolution ([logMAR] range: -0.22 to 1.3; P =0.009) after a mean follow-up period of 10.6 years. Also, patients reported lower vision-related quality of life based on the NEI-VFQ-39 for almost all categories compared to healthy controls. Macular atrophy was diagnosed more often on optical coherence tomography compared to other diagnostic entities. Retinal pigment epithelium detachments in the macula were documented on optical coherence tomography in 56% of the patients. A significant thinning of foveal thickness was measured over time compared to unaffected fellow eyes ( P =0.002). On long-term follow-up, 13 eyes (37%) showed an increase in number of hot spots on fluorescein angiography. Conclusion: This study indicates that cCSC is a progressive disease in many patients, causing a progressive decline in visual acuity, accompanied by lower reported vision-related quality of life. In deciding whether or not to treat, the progressive nature of cCSC should be taken into account in this relatively young and often still professionally active patient group. Keywords: chronic central serous chorioretinopathy, micropulse laser, NEI-VFQ-39, PDT, vision-related quality of life

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2147/opth.s115685

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 158

Metadata

Authors
Breukink, M. B., Dingemans, A. J., den Hollander, A. I., Keunen, J. E., MacLaren, R. E., Fauser, S., Querques, G., Hoyng, C. B., Downes, S. M., & Boon, C. J.
Venue
Clinical Ophthalmology
Published
2016-12
Volume
Volume 11
Pages
39-46
ISSN
  • 1177-5467 (ISSN-L)
  • 1177-5483
OpenAlex
W2563389038
Cited by
158
References
3
FWCI
12.71
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chronic central serous chorioretinopathy: long-term follow-up and vision-related quality of life. https://app.cochat.ai/papers/10.2147/opth.s115685
The paper
Breukink, M. B., Dingemans, A. J., den Hollander, A. I., Keunen, J. E., MacLaren, R. E., Fauser, S., Querques, G., Hoyng, C. B., Downes, S. M., & Boon, C. J. (2016). Chronic central serous chorioretinopathy: long-term follow-up and vision-related quality of life. Clinical Ophthalmology. https://doi.org/10.2147/opth.s115685

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.