Cited by 30Protein Interaction Studies and Fluorescence AnalysisPharmacogenetics and Drug MetabolismEicosanoids and Hypertension Pharmacology

The DOI matches its Crossref record.

In Vitro Plasma Protein Binding of Zileuton and its N-Dehydroxylated Metabolite

Machinist, Joseph M., Kukulka, Michael J., Bopp, Barbara A.·1995·Clinical Pharmacokinetics

Abstract

An ultrafiltration technique or equilibrium dialysis has been used to study the in vitro human plasma protein binding of racemic zileuton, its individual enantiomers, and its pharmacologically inactive metabolite N-dehydroxyzileuton. The plasma protein binding of zileuton and N-dehydroxyzileuton over the concentration range of 0.1 to 100 mg/L averaged 93.1 +/- 0.22 and 92.0 +/- 0.12%, respectively. However, there appeared to be a stereoselective effect, with the R(+) enantiomer of zileuton demonstrating greater binding to plasma proteins than the S(-) enantiomer (96 vs 88%, respectively). Zileuton was bound to both human serum albumin (40 g/L) and alpha 1-acid glycoprotein (1 g/L), although binding affinity to albumin was approximately 3-fold greater. Displacement interactions of zileuton with warfarin, salicylate, theophylline, naproxen, ibuprofen, prednisone, and terfenadine were minimal. The blood to plasma concentration ratio for zileuton and N-dehydroxyzileuton ranged from 0.65 to 0.68, indicating that these compounds were mainly distributed in the plasma. Thus, zileuton is approximately 93% bound to plasma proteins at expected therapeutic concentrations in vitro, and this figure is largely unaffected by several commonly prescribed agents with which the drug may be coadministered.

Overview

Integrity signals

Registry

Crossref · 10.2165/00003088-199500292-00006

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Metadata

Authors
Machinist, J. M., Kukulka, M. J., & Bopp, B. A.
Affiliations
Abbott (United States) (US)
Venue
Clinical Pharmacokinetics
Published
1995
Volume
29
Issue
Supplement 2
Pages
34-41
ISSN
0312-5963 (ISSN-L)
OpenAlex
W2053421289
Cited by
30
References
0
Citations by year
2022: 2 · 2021: 1 · 2019: 1 · 2015: 1
FWCI
1.35
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Pharmacokinetics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Interaction Studies and Fluorescence Analysis
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Pharmacogenetics and Drug Metabolism
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Eicosanoids and Hypertension Pharmacology
Keywords
zileuton, plasma protein binding, stereoselectivity, enantiomers, human serum albumin, alpha-1-acid glycoprotein, drug displacement, pharmacokinetics
MeSH terms
Adult, Anti-Inflammatory Agents, Anticoagulants, Blood Proteins, Chromatography, High Pressure Liquid, Drug Interactions, Female, Hematocrit, Humans, Hydroxylation, Hydroxyurea, Ibuprofen, Isotope Labeling, Male, Naproxen, Prednisolone, Protein Binding, Salicylates, Stereoisomerism, Theophylline, Warfarin, Terfenadine, Lipoxygenase Inhibitors, Anti-Allergic Agents, In Vitro Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review