Cited by 24Water Treatment and DisinfectionWater Systems and OptimizationBacterial biofilms and quorum sensing

The DOI matches its Crossref record.

Haloacetic acid degradation by a biofilm in a simulated drinking water distribution system

Open access
Pluchon, C., Sérodes, J. B., Berthiaume, C., Charette, S. J., Gilbert, Y., Filion, G., Fournier-Larente, J., Rodriguez, M., Duchaine, C.·2013·Water Supply

Abstract

Haloacetic acids (HAAs) are disinfection by-products formed as a result of the reaction between chlorine and natural organic matter found in water. HAA concentrations have been observed to decrease at distribution system extremities. This decrease is associated with microbiological degradation by pipe wall biofilm. The objective of this study was to evaluate HAA degradation in a drinking water system in the presence of a biofilm and to identify the factors that influence this degradation. Degradation of dichloracetic acid (DCAA) and trichloroacetic acid (TCAA) was observed in a simulated distribution system. The results obtained showed that different parameters came into play simultaneously in the degradation of HAAs, including retention time, water temperature, biomass, composition of organic matter, and pipe diameter. Seasonal variations had a major effect on HAA degradation and biomass quantity was lower by 1 to 2 logs in the winter and spring compared with the fall. HAA removal decreased with increasingly large pipe diameters. The specific effects of each of these factors were difficult to isolate from each other owing to interactions.

Overview

Integrity signals

Registry

Crossref · 10.2166/ws.2013.041

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

Metadata

Authors
Pluchon, C., Sérodes, J. B., Berthiaume, C., Charette, S. J., Gilbert, Y., Filion, G., Fournier-Larente, J., Rodriguez, M., & Duchaine, C.
Affiliations
  • Université Laval (CA)
  • Institut universitaire de cardiologie et de pneumologie de Québec (CA)
  • Ecole supérieure d'aménagement du territoire, Laval University, 1628 Pavillon Félix–Antoine-Savard, Québec City, QC, G1K 7P4, Canada
Venue
Water Supply
Published
2013-03-01
Volume
13
Issue
2
Pages
447-461
ISSN
  • 1606-9749 (ISSN-L)
  • 1607-0798
OpenAlex
W2331041159
Cited by
24
References
0
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 5 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 2
FWCI
1.47
Type
journal article
Language
en
Open access
Locations
  • Water Science & Technology Water Supply (publishedVersion)
  • Corpus Université Laval (Université Laval) (submittedVersion)
Funders
  • Université Laval
  • Bundesinstitut für Sportwissenschaft
  • Natural Sciences and Engineering Research Council of Canada
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
  • Physical Sciences › Engineering › Civil and Structural Engineering › Water Systems and Optimization
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Bacterial biofilms and quorum sensing
Keywords
haloacetic acids, disinfection by-products, drinking water distribution systems, dichloroacetate, trichloroacetic acid, microbial degradation, seasonal variation, pipe diameter, retention time, water temperature, biomass, organic matter composition

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review