Microbiological water quality in a large in-building, water recycling facility
The DOI matches its Crossref record.
Abstract
The Thames Water recycling plant at the Millennium Dome, London, reclaimed three sources of water: greywater from the washbasins, rainwater from the Dome roof and groundwater from a borehole on site. These were pre-treated separately, and the mixed stream filtered using ultrafiltration and reverse osmosis membranes. Monitoring for indicator microorganisms was undertaken throughout the plant and in the reclaimed water distribution system, as well as ad-hoc monitoring for the presence of pathogens in the raw waters. Treatment to the level of ultrafiltration was more than adequate to produce a water quality meeting existing worldwide reclaimed water guidelines for toilet flushing. Owing to the excellent quality of the water leaving the plant, no significant microbiological growth was observed in the reclaimed water distribution system during the year. The raw greywater exhibited a higher faecal bacterial load than the rainwater and groundwater, as predicted from more human contact (i.e. hand washing). Environmental strains of Legionella were observed in the three raw greywater samples analysed for pathogens, as was Cryptosporidium, Giardia and faecal enterococci. The rainwater had relatively high levels of faecal bacteria, probably of avian origin. Giardia was detected in one rainwater sample confirming the potential for this water source to contain pathogens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Greywater Characteristics, Treatment Systems, Reuse Strategies and User Perception—a Review
Oteng-Peprah, M., Acheampong, M. A., & deVries, N. K. (2018) · Water, Air, & Soil Pollution · doi:10.1007/s11270-018-3909-8 · Cited by 367
A study of the microbial quality of grey water and an evaluation of treatment technologies for reuse
Winward, G. P., Avery, L. M., Frazer-Williams, R., Pidou, M., Jeffrey, P., Stephenson, T., & Jefferson, B. (2008) · Ecological Engineering · doi:10.1016/j.ecoleng.2007.11.001 · Cited by 228
Microbiological Quality of Roof‐Harvested Rainwater and Health Risks: A Review
Ahmed, W., Gardner, T., & Toze, S. (2011) · Journal of Environmental Quality · doi:10.2134/jeq2010.0345 · Cited by 195
Gilboa, Y., & Friedler, E. (2008) · Water Research · doi:10.1016/j.watres.2007.09.027 · Cited by 130
Microbial quality assessment of household greywater
O’Toole, J., Sinclair, M., Malawaraarachchi, M., Hamilton, A., Barker, S. F., & Leder, K. (2012) · Water Research · doi:10.1016/j.watres.2012.05.001 · Cited by 110
Metadata
- Authors
- Birks, R., Colbourne, J., Hills, S., & Hobson, R.
- Venue
- Water Science and Technology
- Publisher
- IWA Publishing
- Published
- 2004-07-01
- Volume
- 50
- Issue
- 2
- Pages
- 165-172
- ISSN
- 0273-1223 (ISSN-L)
- 1996-9732
- OpenAlex
- W1508572115
- Cited by
- 104
- References
- 0
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbiological water quality in a large in-building, water recycling facility. https://app.cochat.ai/papers/10.2166/wst.2004.0115
- The paper
- Birks, R., Colbourne, J., Hills, S., & Hobson, R. (2004). Microbiological water quality in a large in-building, water recycling facility. Water Science and Technology. https://doi.org/10.2166/wst.2004.0115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.