The DOI matches its Crossref record.
Characterisation of the biosand filter for E. coli reductions from household drinking water under controlled laboratory and field use conditions
Abstract
More than a billion people in the developing world lack access to safe and reliable sources of drinking water. Point of use (POU) household water treatment technology allows people to improve the quality of their water by treating it in the home. One emerging POU technology is the biosand filter (BSF), a household-scale, intermittently operated slow sand filter. Laboratory and field studies examined Escherichia coli reductions achieved by the BSF. During two laboratory studies, mean E. coli reductions were 94% and they improved over the period of filter use, reaching a maximum of 99%. Field analysis conducted on 55 household filters near Bonao, Dominican Republic averaged E. coli reductions of 93%. E. coli reductions by the BSF in laboratory and field studies were less than those typically observed for traditional slow sand filters (SSFs), although as for SSFs microbial reductions improved over the period of filter use. Further study is needed to determine the factors contributing to microbial reductions in BSFs and why reductions are lower than those of conventional SSFs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sobsey, M. D., Stauber, C. E., Casanova, L. M., Brown, J. M., & Elliott, M. A. (2008) · Environmental Science & Technology · doi:10.1021/es702746n · Cited by 710
Self-citationEmergency water supply: A review of potential technologies and selection criteria
Loo, S.-L., Fane, A. G., Krantz, W. B., & Lim, T.-T. (2012) · Water Research · doi:10.1016/j.watres.2012.03.030 · Cited by 255
Microbiological effectiveness and cost of disinfecting water by boiling in semi‐urban India
Clasen, T., McLaughlin, C., Nayaar, N., Boisson, S., Gupta, R., Desai, D., & Shah, N. (2008) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2008.79.407 · Cited by 118
Aiken, B. A., Stauber, C. E., Ortiz, G. M., & Sobsey, M. D. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.09-0122 · Cited by 49
Self-citation
Metadata
- Authors
- Stauber, C. E., Elliott, M. A., Koksal, F., Ortiz, G. M., DiGiano, F. A., & Sobsey, M. D.
- Venue
- Water Science and Technology
- Publisher
- IWA Publishing
- Published
- 2006-08-01
- Volume
- 54
- Issue
- 3
- Pages
- 1-7
- ISSN
- 0273-1223 (ISSN-L)
- 1996-9732
- OpenAlex
- W2130015468
- Cited by
- 179
- References
- 0
- FWCI
- 6.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterisation of the biosand filter for E. coli reductions from household drinking water under controlled laboratory and field use conditions. https://app.cochat.ai/papers/10.2166/wst.2006.440
- The paper
- Stauber, C. E., Elliott, M. A., Koksal, F., Ortiz, G. M., DiGiano, F. A., & Sobsey, M. D. (2006). Characterisation of the biosand filter for E. coli reductions from household drinking water under controlled laboratory and field use conditions. Water Science and Technology. https://doi.org/10.2166/wst.2006.440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.