The Effect of Oral Creatine Supplementation on the Curvature Constant Parameter of the Power-Duration Curve for Cycle Ergometry in Humans.
Open accessThe DOI matches its Crossref record.
Abstract
For high-intensity cycle ergometer exercise, the tolerable duration (t) is well characterized as a hyperbolic function of power output, P : t = W'/(P-thetaF), where thetaF may be termed the "fatigue threshold." The purpose of this study was to determine the effect of oral creatine (Cr) supplementation on the curvature constant parameter (W') of the power-duration curve. A double-blind research method and a cross-over design were employed for creatine/placebo supplementation. Eight healthy male subjects (aged 18 to 22 years) each performed four or five high-intensity square-wave exercise bouts on an electrically braked cycle ergometer after 5 d of Cr monohydrate (CR: 20 g of Cr with artificial sweetener/d) or placebo (PL: 6 g of glucose/d) supplementation. Each subject performed a single high-intensity exercise trial per day for four or five successive days to determination the P-t hyperbolic relation. After 6 weeks (the washout time of Cr from the muscles), each subject performed the other condition (i.e., PL or CR) and repeated the same experimental procedure. There was no significant difference for thetaF between PL and CR conditions (PL: 214.4 +/- 23.6, CR: 207.0 +/- 19.8 W, mean +/- SD). In contrast, W' was significantly increased by the Cr supplementation (PL: 10.9 +/- 2.7, CR: 13.7 +/- 3.0 kJ; p<0.05). The results indicated that Cr and/or PCr content in muscles seems to be one of the important determinants of the curvature constant parameter (W') of the power-duration hyperbolic curve for cycle ergometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Critical Power: Implications for Determination of V˙O2max and Exercise Tolerance
JONES, A. M., VANHATALO, A., BURNLEY, M., MORTON, R. H., & POOLE, D. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d9cf7f · Cited by 549
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Muscle metabolic responses to exercise above and below the “critical power” assessed using31P-MRS
Jones, A. M., Wilkerson, D. P., DiMenna, F., Fulford, J., & Poole, D. C. (2008) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00731.2007 · Cited by 478
Oxygen uptake kinetics as a determinant of sports performance
Burnley, M., & Jones, A. M. (2007) · European Journal of Sport Science · doi:10.1080/17461390701456148 · Cited by 467
Effect of creatine supplementation on body composition and performance: a meta-analysis
Branch, J. D. (2003) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.13.2.198 · Cited by 309
Metadata
- Authors
- MIURA, A., KINO, F., KAJITANI, S., SATO, H., SATO, H., & FUKUBA, Y.
- Venue
- The Japanese Journal of Physiology
- Publisher
- Physiological Society of Japan
- Published
- 1999
- Volume
- 49
- Issue
- 2
- Pages
- 169-174
- ISSN
- 0021-521X (ISSN-L)
- OpenAlex
- W2044600943
- Cited by
- 94
- References
- 0
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Oral Creatine Supplementation on the Curvature Constant Parameter of the Power-Duration Curve for Cycle Ergometry in Humans. https://app.cochat.ai/papers/10.2170/jjphysiol.49.169
- The paper
- MIURA, A., KINO, F., KAJITANI, S., SATO, H., SATO, H., & FUKUBA, Y. (1999). The Effect of Oral Creatine Supplementation on the Curvature Constant Parameter of the Power-Duration Curve for Cycle Ergometry in Humans. The Japanese Journal of Physiology. https://doi.org/10.2170/jjphysiol.49.169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.