The DOI matches its Crossref record.
ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals
Open accessAbstract
The ECAT was designed and developed as a positron imaging system capable of providing high contrast, high resolution, quantitative images in two-dimensional (2-D) and tomographic formats. The flexibility in its variety of imaging problems. High (HR), medium (MR), and low (LR) tomographic resolutions are 0.95 +/- 0.1, 1.3 +/- 0.1, and 1.7 +/- 0.1 cm FWHM; high, medium, and low resolutions in 2-D images are 0.85 +/- 0.1, 1.3 +/- 0.1 and 1.7 +/- 0.1, depending on resolution mode employed. ECT system efficiency is 30,100, 15,900, and 9,200 c/sec/muCi/cc with a 20-cm diameter phantom at LR, MR, and HR. Because of the geometric, detector, electronic and shielding design of the system, count-rate capability and linearity are high, with minimum detection of scattered radiation and random coincidence. Measured error agrees well with theoretical statistical predictions down to a level of 1.4% standard deviation. The redundant sampling scheme of this system significantly reduces errors caused by motion and detector instability. Scan times are variable from 10 sec to several min/slice and multiple levels are automatically performed by computer control of patient bed. A variety of human studies illustrate image quality, resolution, and efficiency of both ECT and 2-D imaging mode. Examples of the noninvasive study method have been made possible through development of ECT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phelps, M. E., Huang, S. C., Hoffman, E. J., Selin, C., Sokoloff, L., & Kuhl, D. E. (1979) · Annals of Neurology · doi:10.1002/ana.410060502 · Cited by 2,418
Self-citationNoninvasive determination of local cerebral metabolic rate of glucose in man
Huang, S. C., Phelps, M. E., Hoffman, E. J., Sideris, K., Selin, C. J., & Kuhl, D. E. (1980) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1980.238.1.e69 · Cited by 925
Self-citationKuhl, D. E., Engel, J., Phelps, M. E., & Selin, C. (1980) · Annals of Neurology · doi:10.1002/ana.410080403 · Cited by 420
Self-citationThe Fluorodeoxyglucose 18F Scan in Alzheimer's Disease and Multi-infarct Dementia
Benson, D. F., Kuhl, D. E., Hawkins, R. A., Phelps, M. E., Cummings, J. L., & Tsai, S. Y. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050110029003 · Cited by 392
Self-citationStudy of Cerebral Function with Positron Computed Tomography
Phelps, M. E., Mazziotta, J. C., & Huang, S.-C. (1982) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1982.14 · Cited by 378
Self-citation
Metadata
- Authors
- Phelps, M. E., Hoffman, E. J., Huang, S. C., & Kuhl, D. E.
- Published
- 1977-01-01
- Volume
- 19
- Issue
- 6
- Pages
- 635-47
- OpenAlex
- W2110435361
- Cited by
- 241
- References
- 0
- Type
- report
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals. https://app.cochat.ai/papers/10.2172/5423721
- The paper
- Phelps, M. E., Hoffman, E. J., Huang, S. C., & Kuhl, D. E. (1977). ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals. https://doi.org/10.2172/5423721
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.