Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin
Open accessThe DOI matches its Crossref record.
Abstract
In this study, we measured and documented summertime air-conditioning (a/c) daily energy savings and demand reduction from a reflective roof membrane retrofit on a large retail store in Austin, Texas. The original black rubber membrane was replaced with white thermoplastic resulting in a decrease in the average maximum roof surface temperature from 168 degrees F (76 degrees C) to 126 degrees F (52 degrees C). This building, with 100,000ft2 (9300m2) of roof area, yielded 3.6Wh/ft2 (39Wh/m2) in a/c average daily energy savings and 0.35W/ft2 (3.8W/m2) in average reduced demand. Total a/c annual abated energy and demand expenditures were estimated to be $7200 or $0.072/ft2 ($0.77/m2). Based on cost data provided by the building manager, the payback is instantaneous with negligible incremental combined labor and material costs. The estimated present value of future abated expenditures ranged from $62,000 to $71,000 over the baseline 13-year service life of the roof membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synnefa, A., Santamouris, M., & Apostolakis, K. (2007) · Solar Energy · doi:10.1016/j.solener.2006.08.005 · Cited by 563
de_Richter, R., & Caillol, S. (2011) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2011.05.002 · Cited by 234
Cooler tile-roofed buildings with near-infrared-reflective non-white coatings
Levinson, R., Akbari, H., & Reilly, J. C. (2007) · Building and Environment · doi:10.1016/j.buildenv.2006.06.005 · Cited by 233
Self-citationCool roof technology in London: An experimental and modelling study
Kolokotroni, M., Gowreesunker, B. L., & Giridharan, R. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2011.07.011 · Cited by 191
“A number of papers have been published for residential buildings [1, 2, 3, 4, 5, 6], retail stores [7], and other commercial buildings [8,9].”
BackgroundMonitoring the energy-use effects of cool roofs on California commercial buildings
Akbari, H., Levinson, R., & Rainer, L. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.11.013 · Cited by 177
Self-citation
Metadata
- Authors
- Konopacki, S. J., & Akbari, H.
- Published
- 2001-06-25
- OpenAlex
- W1550762909
- Cited by
- 78
- References
- 0
- Type
- report
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin. https://app.cochat.ai/papers/10.2172/787107
- The paper
- Konopacki, S. J., & Akbari, H. (2001). Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin. https://doi.org/10.2172/787107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.