The DOI matches its Crossref record.
Frequency Regulation Basics and Trends
Open accessAbstract
The electric power system must address two unique requirements: the need to maintain a near real-time balance between generation and load, and the need to adjust generation (or load) to manage power flows through individual transmission facilities. These requirements are not new: vertically integrated utilities have been meeting them for a century as a normal part of conducting business. With restructuring, however, the services needed to meet these requirements, now called ''ancillary services'', are being more clearly defined. Ancillary services are those functions performed by the equipment and people that generate, control, and transmit electricity in support of the basic services of generating capacity, energy supply, and power delivery. The Federal Energy Regulatory Commission (FERC) has defined such services as those ''necessary to support the transmission of electric power from seller to purchaser given the obligations of control areas and transmitting utilities within those control areas to maintain reliable operations of the interconnected transmission system''. This statement recognizes the importance of ancillary services for both bulk-power reliability and support of commercial transactions. Balancing generation and load instantaneously and continuously is difficult because loads and generators are constantly fluctuating. Minute-to-minute load variability results from the random turning on and off of millions of individual loads. Longer-term variability results from predictable factors such as the daily and seasonal load patterns as well as more random events like shifting weather patterns. Generators also introduce unexpected fluctuations because they do not follow their generation schedules exactly and they trip unexpectedly due to a range of equipment failures. The output from wind generators varies with the wind. Storage technologies should be ideal suppliers of several ancillary services, including regulation, contingency reserves (spinning reserve, supplemental reserve, replacement reserve), and voltage support. These services are not free; in regions with energy markets, generators are paid to supply these services. In vertically integrated utilities (without energy markets) the utility incurs significant costs to supply these services. Supplying these services may be a significant business opportunity for emerging storage technologies. This report briefly explores the various ancillary services that may be of interest to storage. It then focuses on regulation, the most expensive ancillary service. It also examines the impact that increasing amounts of wind generation may have on regulation requirements, decreasing conventional regulation supplies, and the implications for energy storage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Energy Storage with Renewable Electricity Generation
Denholm, P., Ela, E., Kirby, B., & Milligan, M. (2010) · doi:10.2172/972169 · Cited by 847
Self-citationRenewable energy sources and frequency regulation: survey and new perspectives
Bevrani, H., Ghosh, A., & Ledwich, G. (2010) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2009.0049 · Cited by 574
Brooks, A., Lu, E., Reicher, D., Spirakis, C., & Weihl, B. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2010.936349 · Cited by 424
Vehicle-to-Aggregator Interaction Game
Wu, C., Mohsenian-Rad, H., & Huang, J. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2166414 · Cited by 393
A review of flywheel energy storage systems: state of the art and opportunities
Li, X., & Palazzolo, A. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2021.103576 · Cited by 348
Metadata
- Authors
- Kirby, B. J.
- Published
- 2005-05-06
- OpenAlex
- W2149519601
- Cited by
- 177
- References
- 0
- Type
- report
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency Regulation Basics and Trends. https://app.cochat.ai/papers/10.2172/885974
- The paper
- Kirby, B. J. (2005). Frequency Regulation Basics and Trends. https://doi.org/10.2172/885974
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.