The DOI matches its Crossref record.
Differential Scanning Calorimetry in Life Science: Thermodynamics, Stability, Molecular Recognition and Application in Drug Design
Open accessAbstract
All biological phenomena depend on molecular recognition, which is either intermolecular like in ligand binding to a macromolecule or intramolecular like in protein folding. As a result, understanding the relationship between the structure of proteins and the energetics of their stability and binding with others (bio)molecules is a very interesting point in biochemistry and biotechnology. It is essential to the engineering of stable proteins and to the structure-based design of pharmaceutical ligands. The parameter generally used to characterize the stability of a system (the folded and unfolded state of the protein for example) is the equilibrium constant (K) or the free energy (deltaG(o)), which is the sum of enthalpic (deltaH(o)) and entropic (deltaS(o)) terms. These parameters are temperature dependent through the heat capacity change (deltaCp). The thermodynamic parameters deltaH(o) and deltaCp can be derived from spectroscopic experiments, using the van't Hoff method, or measured directly using calorimetry. Along with isothermal titration calorimetry (ITC), differential scanning calorimetry (DSC) is a powerful method, less described than ITC, for measuring directly the thermodynamic parameters which characterize biomolecules. In this article, we summarize the principal thermodynamics parameters, describe the DSC approach and review some systems to which it has been applied. DSC is much used for the study of the stability and the folding of biomolecules, but it can also be applied in order to understand biomolecular interactions and can thus be an interesting technique in the process of drug design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analysis of Protein Stability and Ligand Interactions by Thermal Shift Assay
Huynh, K., & Partch, C. L. (2015) · Current Protocols in Protein Science · doi:10.1002/0471140864.ps2809s79 · Cited by 575
Marine Origin Collagens and Its Potential Applications
Silva, T., Moreira-Silva, J., Marques, A., Domingues, A., Bayon, Y., & Reis, R. (2014) · Marine Drugs · doi:10.3390/md12125881 · Cited by 452
Biophysics in drug discovery: impact, challenges and opportunities
Renaud, J.-P., Chung, C.-W., Danielson, U. H., Egner, U., Hennig, M., Hubbard, R. E., & Nar, H. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.123 · Cited by 382
Prenner, E., & Chiu, M. (2011) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/0975-7406.76463 · Cited by 373
Liu, X., Le Bourvellec, C., & Renard, C. M. G. C. (2020) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12632 · Cited by 295
Metadata
- Authors
- Bruylants, G., Wouters, J., & Michaux, C.
- Venue
- Current Medicinal Chemistry
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2005-08-01
- Volume
- 12
- Issue
- 17
- Pages
- 2011-2020
- ISSN
- 0929-8673 (ISSN-L)
- OpenAlex
- W2135676217
- Cited by
- 331
- References
- 0
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential Scanning Calorimetry in Life Science: Thermodynamics, Stability, Molecular Recognition and Application in Drug Design. https://app.cochat.ai/papers/10.2174/0929867054546564
- The paper
- Bruylants, G., Wouters, J., & Michaux, C. (2005). Differential Scanning Calorimetry in Life Science: Thermodynamics, Stability, Molecular Recognition and Application in Drug Design. Current Medicinal Chemistry. https://doi.org/10.2174/0929867054546564
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.