CoChat

Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods

Millasseau, Sandrine, Agnoletti, Davide · 2014 · Current Pharmaceutical Design
Cited by 50

The DOI matches its Crossref record.

Abstract

While for years clinicians have used cuff pressure to assess patients' cardiovascular risk, recent evidences has shown that aortic pressure, or more specifically aortic systolic and aortic pulse pressures, have a better prognostic value to predict cardiovascular events and mortality. This led to the emergence of multiple methods and devices to assess aortic pressure non-invasively. Some use scaled waveforms measured at the carotid level with tonometry, or ultrasounds. Others use transfer function or mathematical modelling from radial or brachial traces acquired from volume plethsymography or applanation tonometry. Not all these techniques are equivalent and most of them have the major flaw of using brachial cuff pressure to scale their results. The purpose of this review is to present the strengths and weaknesses of techniques and various commercial devices to estimate aortic systolic pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2174/1381612820666141023163748

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Millasseau, S., & Agnoletti, D.
Venue
Current Pharmaceutical Design
Published
2014-12-16
Volume
21
Issue
6
Pages
709-718
ISSN
1381-6128 (ISSN-L)
OpenAlex
W2332345204
Cited by
50
References
0
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods. https://app.cochat.ai/papers/10.2174/1381612820666141023163748
The paper
Millasseau, S., & Agnoletti, D. (2014). Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods. Current Pharmaceutical Design. https://doi.org/10.2174/1381612820666141023163748

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.