Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods
The DOI matches its Crossref record.
Abstract
While for years clinicians have used cuff pressure to assess patients' cardiovascular risk, recent evidences has shown that aortic pressure, or more specifically aortic systolic and aortic pulse pressures, have a better prognostic value to predict cardiovascular events and mortality. This led to the emergence of multiple methods and devices to assess aortic pressure non-invasively. Some use scaled waveforms measured at the carotid level with tonometry, or ultrasounds. Others use transfer function or mathematical modelling from radial or brachial traces acquired from volume plethsymography or applanation tonometry. Not all these techniques are equivalent and most of them have the major flaw of using brachial cuff pressure to scale their results. The purpose of this review is to present the strengths and weaknesses of techniques and various commercial devices to estimate aortic systolic pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accuracy of Cuff-Measured Blood Pressure
Picone, D. S., Schultz, M. G., Otahal, P., Aakhus, S., Al-Jumaily, A. M., Black, J. A., Bos, W. J., Chambers, J. B., Chen, C.-H., Cheng, H.-M., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.05.064 · Cited by 277
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
“oscillometric sub-diastolic or supra-systolic waveform analysis with generalized transfer functions), which employ a variety of signal processing steps to estimate central BP from peripheral signals.(17,18) Yet, with no standardized guidelines,(17) the accuracy testing of these new devices (as well as the preceding de…”
BackgroundSelf-citationSharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
Measurements of arterial pressure and flow in vivo
Sharman, J. E., Segers, P., & Chirinos, J. A. (2022) · Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease · doi:10.1016/b978-0-323-91391-1.00002-9 · Cited by 3
Metadata
- Authors
- Millasseau, S., & Agnoletti, D.
- Venue
- Current Pharmaceutical Design
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2014-12-16
- Volume
- 21
- Issue
- 6
- Pages
- 709-718
- ISSN
- 1381-6128 (ISSN-L)
- OpenAlex
- W2332345204
- Cited by
- 50
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods. https://app.cochat.ai/papers/10.2174/1381612820666141023163748
- The paper
- Millasseau, S., & Agnoletti, D. (2014). Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods. Current Pharmaceutical Design. https://doi.org/10.2174/1381612820666141023163748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.