The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Acoustic Radiation Force Impulse (ARFI) Imaging: A Review
Open accessAbstract
Acoustic radiation force based elasticity imaging methods are under investigation by many groups. These methods differ from traditional ultrasonic elasticity imaging methods in that they do not require compression of the transducer, and are thus expected to be less operator dependent. Methods have been developed that utilize impulsive (i.e. < 1 ms), harmonic (pulsed), and steady state radiation force excitations. The work discussed herein utilizes impulsive methods, for which two imaging approaches have been pursued: 1) monitoring the tissue response within the radiation force region of excitation (ROE) and generating images of relative differences in tissue stiffness (Acoustic Radiation Force Impulse (ARFI) imaging); and 2) monitoring the speed of shear wave propagation away from the ROE to quantify tissue stiffness (Shear Wave Elasticity Imaging (SWEI)). For these methods, a single ultrasound transducer on a commercial ultrasound system can be used to both generate acoustic radiation force in tissue, and to monitor the tissue displacement response. The response of tissue to this transient excitation is complicated and depends upon tissue geometry, radiation force field geometry, and tissue mechanical and acoustic properties. Higher shear wave speeds and smaller displacements are associated with stiffer tissues, and slower shear wave speeds and larger displacements occur with more compliant tissues. ARFI images have spatial resolution comparable to that of B-mode, often with greater contrast, providing matched, adjunctive information. SWEI images provide quantitative information about the tissue stiffness, typically with lower spatial resolution. A review these methods and examples of clinical applications are presented herein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Self-citationTanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Quantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683
Self-citationSelected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
Ultrasound-Stimulated Vibro-Acoustic Spectrography
Fatemi, M., & Greenleaf, J. F. (1998) · Science · doi:10.1126/science.280.5360.82 · Cited by 642
Friedrich-Rust, M., Wunder, K., Kriener, S., Sotoudeh, F., Richter, S., Bojunga, J., Herrmann, E., Poynard, T., Dietrich, C. F., Vermehren, J., et al. (2009) · Radiology · doi:10.1148/radiol.2523081928 · Cited by 620
Shear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412
Muller, M., Gennisson, J.-L., Deffieux, T., Tanter, M., & Fink, M. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.08.018 · Cited by 400
Rapid tracking of small displacements with ultrasound
Pinton, G. F., Dahl, J. J., & Trahey, G. E. (2006) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1642509 · Cited by 389
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Lupșor‐Platon, M., Badea, R. I., Ştefănescu, H., Sparchez, Z. A., Branda, H., Serban, A., & Maniu, A. (2009) · PubMed · Cited by 274
On the thermal effects associated with radiation force imaging of soft tissue
Palmeri, M. L., & Nightingale, K. R. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320828 · Cited by 155
Self-citationIn Vivo Assessment of Myocardial Stiffness with Acoustic Radiation Force Impulse Imaging
Hsu, S. J., Bouchard, R. R., Dumont, D. M., Wolf, P. D., & Trahey, G. E. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.05.009 · Cited by 119
Dahl, J., Dumont, D. M., Allen, J. D., Miller, E. M., & Trahey, G. E. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.11.001 · Cited by 107
Fahey, B. J., Nightingale, K. R., McAleavey, S. A., Palmeri, M. L., Wolf, P. D., & Trahey, G. E. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1428046 · Cited by 95
Self-citationCharacterizing Stiffness of Human Prostates Using Acoustic Radiation Force
Zhai, L., Madden, J. F., Foo, W., MOURAVIEV, V. B., Polascik, T. J., Palmeri, M. L., & Nightingale, K. R. (2010) · Ultrasonic Imaging · doi:10.1177/016173461003200401 · Cited by 63
Self-citationEyerly‐Webb, S. A., Hsu, S. J., Agashe, S. H., Trahey, G. E., Li, Y., & Wolf, P. D. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01664.x · Cited by 52
Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring
Konofagou, E. E., Maleke, C., & Vappou, J. (2012) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/157340512799220616 · Cited by 47
Cited by
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
Barr, R. G., Ferraioli, G., Palmeri, M. L., Goodman, Z. D., Garcia-Tsao, G., Rubin, J., Garra, B., Myers, R. P., Wilson, S. R., Rubens, D., et al. (2015) · Radiology · doi:10.1148/radiol.2015150619 · Cited by 632
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Deep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Metadata
- Authors
- Nightingale, K.
- Venue
- Current Medical Imaging Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2011-11-01
- Volume
- 7
- Issue
- 4
- Pages
- 328-339
- ISSN
- 1573-4056 (ISSN-L)
- OpenAlex
- W1971183419
- Cited by
- 408
- References
- 21
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.