Fast Healthcare Interoperability Resources (FHIR) for Interoperability in Health Research: Systematic Review
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: The standard Fast Healthcare Interoperability Resources (FHIR) is widely used in health information technology. However, its use as a standard for health research is still less prevalent. To use existing data sources more efficiently for health research, data interoperability becomes increasingly important. FHIR provides solutions by offering resource domains such as “Public Health & Research” and “Evidence-Based Medicine” while using already established web technologies. Therefore, FHIR could help standardize data across different data sources and improve interoperability in health research. Objective: The aim of our study was to provide a systematic review of existing literature and determine the current state of FHIR implementations in health research and possible future directions. Methods: We searched the PubMed/MEDLINE, Embase, Web of Science, IEEE Xplore, and Cochrane Library databases for studies published from 2011 to 2022. Studies investigating the use of FHIR in health research were included. Articles published before 2011, abstracts, reviews, editorials, and expert opinions were excluded. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered this study with PROSPERO (CRD42021235393). Data synthesis was done in tables and figures. Results: We identified a total of 998 studies, of which 49 studies were eligible for inclusion. Of the 49 studies, most (73%, n=36) covered the domain of clinical research, whereas the remaining studies focused on public health or epidemiology (6%, n=3) or did not specify their research domain (20%, n=10). Studies used FHIR for data capture (29%, n=14), standardization of data (41%, n=20), analysis (12%, n=6), recruitment (14%, n=7), and consent management (4%, n=2). Most (55%, 27/49) of the studies had a generic approach, and 55% (12/22) of the studies focusing on specific medical specialties (infectious disease, genomics, oncology, environmental health, imaging, and pulmonary hypertension) reported their solutions to be conferrable to other use cases. Most (63%, 31/49) of the studies reported using additional data models or terminologies: Systematized Nomenclature of Medicine Clinical Terms (29%, n=14), Logical Observation Identifiers Names and Codes (37%, n=18), International Classification of Diseases 10th Revision (18%, n=9), Observational Medical Outcomes Partnership common data model (12%, n=6), and others (43%, n=21). Only 4 (8%) studies used a FHIR resource from the domain “Public Health & Research.” Limitations using FHIR included the possible change in the content of FHIR resources, safety, legal matters, and the need for a FHIR server. Conclusions: Our review found that FHIR can be implemented in health research, and the areas of application are broad and generalizable in most use cases. The implementation of international terminologies was common, and other standards such as the Observational Medical Outcomes Partnership common data model could be used as a complement to FHIR. Limitations such as the change of FHIR content, lack of FHIR implementation, safety, and legal matters need to be addressed in future releases to expand the use of FHIR and, therefore, interoperability in health research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayyan-a web and mobile app for systematic reviews.
Ouzzani, M., Hammady, H., Fedorowicz, Z., & Elmagarmid, A. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0384-4 · Cited by 26,092
Wickham, H., Averick, M., Bryan, J., Chang, W., McGowan, L., François, R., Grolemund, G., Hayes, A., Henry, L., Hester, J., et al. (2019) · Journal of Open Source Software · doi:10.21105/joss.01686 · Cited by 22,138 · cited 1×
“5; R Foundation for Statistical Computing) [19] and the tidyverse packages [20].”
BackgroundThe FAIR Guiding Principles for scientific data management and stewardship
Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J., Appleton, G., Axton, M., Baak, A., Blomberg, N., Boiten, J.-W., da Silva Santos, L. B., Bourne, P. E., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.18 · Cited by 18,423
Publication Bias in Editorial Decision Making
Olson, C. M. (2002) · JAMA · doi:10.1001/jama.287.21.2825 · Cited by 395 · cited 1×
“Furthermore, we assumed that the published literature provides a surplus on successful FHIR initiatives because, in general, unsuccessful initiatives tend to stay unpublished [78].”
BackgroundThe Use of FHIR in Digital Health – A Review of the Scientific Literature
Moritz, L., Sandra, L., Paulina, V. F. G. I., & Sylvia, T. (2019) · Studies in Health Technology and Informatics · doi:10.3233/shti190805 · Cited by 88
Braunstein, M. L. (2018) · Health Informatics on FHIR: How HL7's New API is Transforming Healthcare · doi:10.1007/978-3-319-93414-3_9 · Cited by 83
Cited by
Bias in medical AI: Implications for clinical decision-making
Cross, J. L., Choma, M. A., & Onofrey, J. A. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000651 · Cited by 607
Wang, Z., Zhang, Z., Traverso, A., Dekker, A., Qian, L., & Sun, P. (2024) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-23-1180 · Cited by 46
Metadata
- Authors
- Vorisek, C. N., Lehne, M., Klopfenstein, S. A. I., Mayer, P. J., Bartschke, A., Haese, T., & Thun, S.
- Venue
- JMIR Medical Informatics
- Publisher
- JMIR Publications Inc.
- Published
- 2022-07-19
- Volume
- 10
- Issue
- 7
- Pages
- e35724
- ISSN
- 2291-9694 (ISSN-L)
- OpenAlex
- W4285315819
- Cited by
- 247
- References
- 6
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.