Impact of Computer-Aided Detection in a Regional Screening Mammography Program
The DOI matches its Crossref record.
Abstract
OBJECTIVE: This study was conducted to prospectively assess the effect of computer-aided detection (CAD) on screening outcomes in a regional mammography program. MATERIALS AND METHODS: Between January 1, 1998, and December 31, 2000, 27,274 consecutive screenings were performed. Radiologists' performance before CAD (n = 7,872) and with CAD (n = 19,402) was determined by annual audits. All positive biopsy results were reviewed; histopathology was reviewed and confirmed. Outcomes (recall, biopsy, and cancer detection rates) with CAD (1999, 2000) were compared with historical control data (1998). RESULTS: With CAD, increases were seen in recall rate (8.1%, from 7.7% to 8.3%), biopsy rate (6.7%, from 1.4% to 1.5%), and cancer detection rate (16.1%, from 3.7 per 1,000 to 4.3 per 1,000). Detection rate of invasive cancers of 1.0 cm or less increased 164% (from 0.508 to 1.34 per 1,000 screens; p = 0.069). Detection rate of in situ cancers declined 6.7% (from 1.27 to 1.19 per 1,000; p = 0.849). In multivariable analysis of invasive cancers, early stage (stage I) was strongly associated with detection by CAD (odds ratio = 4.13, p = 0.025). Mean age at screening detection of cancer was 5.3 years younger in the CAD group than in the pre-CAD group (p = 0.060). CONCLUSION: Increased detection rate, younger age at diagnosis, and significantly earlier stage of invasive cancer detection are consistent with a positive screening impact of CAD. Audit results were positive but generally not statistically significant due to sample size limitations. Our findings support the hypothesis that screening with CAD significantly improves detection of the specific cancer morphologies that CAD algorithms were designed to detect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[4] Cupples TE, Cunningham JE, Reynolds JC.”
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
The Potential of Radiomic-Based Phenotyping in Precision Medicine: A Review
Aerts, H. J. W. L. (2016) · JAMA Oncology · doi:10.1001/jamaoncol.2016.2631 · Cited by 669
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Metadata
- Authors
- Cupples, T. E., Cunningham, J. E., & Reynolds, J. C.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2005-10
- Volume
- 185
- Issue
- 4
- Pages
- 944-950
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2140259714
- Cited by
- 149
- References
- 0
- FWCI
- 14.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Computer-Aided Detection in a Regional Screening Mammography Program. https://app.cochat.ai/papers/10.2214/ajr.04.1300
- The paper
- Cupples, T. E., Cunningham, J. E., & Reynolds, J. C. (2005). Impact of Computer-Aided Detection in a Regional Screening Mammography Program. American Journal of Roentgenology. https://doi.org/10.2214/ajr.04.1300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.