Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Improved Cancer Detection Using Computer-Aided Detection with Diagnostic and Screening Mammography: Prospective Study of 104 Cancers

Dean, Judy C., Ilvento, Christina C.·2006·American Journal of Roentgenology

Abstract

OBJECTIVE: This study prospectively evaluated a computer-aided detection (CAD) device used with diagnostic and screening mammography by assessing cancers detected; tumor sizes, histology, and stage; positive predictive value (PPV) of biopsy recommendation; and recall rates before and after CAD introduction. SUBJECTS AND METHODS: Interpretations of 9,520 consecutive mammograms were recorded without and then with CAD for a 28-month period. Cancer detections based on initial radiologist review and additional detections based on CAD findings were noted. Recall rates, tumor size and histology, and PPV of biopsy recommendation before and after the introduction of CAD were compared. RESULTS: Cancers detected only with CAD assistance were 9.6% of all cancers (10 of 104); screening-detected cancers increased 13.3% with CAD assistance (four in addition to 30 screening-detected cancers). The 95% one-sided confidence boundary using binomial distribution is consistent with at least 5.3% for all cancers and 5.1% for nonpalpable cancers. The greatest impact was on ductal carcinoma in situ, for which CAD increased cancer detection by 14.2% (three added to 21). Similar percentages of cancers were detected only with CAD assistance in both screening (11.4%; 4 of 35) and diagnostic (9.5%; six of 63) studies. Additional cancers were detected using CAD in patients with implants and previous lumpectomy. The additional cancers detected with CAD were smaller (p = 0.01 for all cancers, p = 0.03 for nonpalpable invasive cancer). The screening recall rate increased from 6.2% to 7.8% after CAD, with a decrease in the biopsy rate and a nonsignificant increase in the biopsy PPV from 21.9% to 26.3%. CONCLUSION: CAD resulted in detection of more cancers in screening and diagnostic patients, with an increased recall rate but no deterioration in PPV of biopsy. Additional cancers detected were significantly smaller.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.05.0111

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Dean, J. C., & Ilvento, C. C.
Venue
American Journal of Roentgenology
Published
2006-07
Volume
187
Issue
1
Pages
20-28
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2112834177
Cited by
163
References
1
FWCI
13.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Cancer Detection Using Computer-Aided Detection with Diagnostic and Screening Mammography: Prospective Study of 104 Cancers. https://app.cochat.ai/papers/10.2214/ajr.05.0111
The paper
Dean, J. C., & Ilvento, C. C. (2006). Improved Cancer Detection Using Computer-Aided Detection with Diagnostic and Screening Mammography: Prospective Study of 104 Cancers. American Journal of Roentgenology. https://doi.org/10.2214/ajr.05.0111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.