The DOI matches its Crossref record.
Use of the “Two-Slice-Touch” Rule for the MRI Diagnosis of Meniscal Tears
Open accessAbstract
OBJECTIVE: We reviewed our experience with knee MRI to determine if using the "two-slice-touch" rule increased our positive predictive value for diagnosing meniscal tears. This rule classifies a meniscus as torn if there are two or more MR images with abnormal findings and as possibly torn if there is only one MR image with an abnormal finding. We also compared our sensitivity and specificity using fast spin-echo imaging with previously reported studies. MATERIALS AND METHODS: We reviewed the medical records of 174 patients who had knee MR examinations and correlative knee arthroscopy to determine our accuracy when we diagnosed menisci as torn, possibly torn, or intact using knee arthroscopy as the gold standard. RESULTS: Our positive predictive value increased from 91% to 94% (p = 0.37) for medial meniscal tears and from 83% to 96% (p = 0.02) for lateral meniscal tears when using the two-slice-touch rule compared with the standard criterion of diagnosing a meniscus as torn if one or more images are abnormal. When using the standard criterion, we had 95% sensitivity and 85% specificity for diagnosing medial meniscal tears and 77% sensitivity and 89% specificity for diagnosing lateral meniscal tears. CONCLUSION: When using the two-slice-touch rule, we had an increased positive predictive value for diagnosing menisci as torn, which was statistically significant for the lateral meniscus. Our accuracy using the standard criterion with fast spin-echo imaging was comparable to that reported in previous studies with spin-echo imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Incidental Meniscal Findings on Knee MRI in Middle-Aged and Elderly Persons
Englund, M., Guermazi, A., Gale, D., Hunter, D. J., Aliabadi, P., Clancy, M., & Felson, D. T. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800777 · Cited by 921
Bien, N., Rajpurkar, P., Ball, R. L., Irvin, J., Park, A., Jones, E., Bereket, M., Patel, B. N., Yeom, K. W., Shpanskaya, K., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002699 · Cited by 734
Diagnosis of osteoarthritis: Imaging
Braun, H. J., & Gold, G. E. (2012) · Bone · doi:10.1016/j.bone.2011.11.019 · Cited by 402
Meniscus pathology, osteoarthritis and the treatment controversy
Englund, M., Roemer, F. W., Hayashi, D., Crema, M. D., & Guermazi, A. (2012) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.69 · Cited by 385
The role of the meniscus in knee osteoarthritis: a cause or consequence?
Englund, M., Guermazi, A., & Lohmander, S. L. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2009.03.003 · Cited by 274
Metadata
- Authors
- De Smet, A. A., & Tuite, M. J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2006-10
- Volume
- 187
- Issue
- 4
- Pages
- 911-914
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2109715888
- Cited by
- 163
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of the “Two-Slice-Touch” Rule for the MRI Diagnosis of Meniscal Tears. https://app.cochat.ai/papers/10.2214/ajr.05.1354
- The paper
- De Smet, A. A., & Tuite, M. J. (2006). Use of the “Two-Slice-Touch” Rule for the MRI Diagnosis of Meniscal Tears. American Journal of Roentgenology. https://doi.org/10.2214/ajr.05.1354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.