Comparative Accuracy of Renal Duplex Sonographic Parameters in the Diagnosis of Renal Artery Stenosis: Paired and Unpaired Analysis

Open access
Williams, Gabrielle J., Macaskill, Petra, Chan, Siew F., Karplus, Thomas E., Yung, Winkle, Hodson, Elisabeth M., Craig, Jonathan C. · 2007 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to evaluate the test performance of duplex sonographic parameters in screening for hemodynamically significant renal artery stenosis, which occurs in approximately 5% of persons with hypertension. MATERIALS AND METHODS: A comprehensive literature search was conducted to find studies on the diagnosis of renal artery stenosis in which duplex sonography and intraarterial angiography were compared and in which sensitivity and specificity were calculated. MEDLINE (1966-2005), EMBASE (1988-2005), and reference lists were searched and the authors contacted. Data were subjected to meta-analysis according to the hierarchical summary receiver operating characteristic curve model. Heterogeneity in test performance relating to population and design features was investigated. RESULTS: From 1,357 titles, 88 studies involving 9,974 arteries in 8,147 patients were included. The following four parameters were evaluated: peak systolic velocity (21 studies), acceleration time (13 studies), acceleration index (13 studies), and renal-aortic ratio (13 studies). The corresponding diagnostic odds ratios (ORs) were 60.9 (95% CI, 28.3-131.2), 28.9 (95% CI, 7.1-117.2), 16.0 (95% CI, 5.1-50.6), and 29.3 (95% CI, 12.7-67.7). Results based on studies in which parameters were directly compared showed that peak systolic velocity had greater accuracy than renal-aortic ratio (relative diagnostic OR, 1.8; p = 0.03; nine studies) and acceleration index (relative diagnostic OR, 5.3; p < 0.001; five studies). Acceleration time versus acceleration index showed no evidence of a difference in accuracy (relative diagnostic OR, 1.1; p = 0.65; nine studies). Analysis of peak systolic velocity used in combination with other parameters compared with peak systolic velocity alone (seven studies) showed evidence of a shift in test positivity (p < 0.001) but only weak evidence of improvement in accuracy (relative diagnostic OR, 1.6; p = 0.09). CONCLUSION: Sonography is a moderately accurate screening test for renal artery stenosis. The single measurement, peak systolic velocity, has the highest performance characteristics, an expected sensitivity of 85% and specificity of 92%. Additional measurements do not increase accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.06.0355

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Williams, G. J., Macaskill, P., Chan, S. F., Karplus, T. E., Yung, W., Hodson, E. M., & Craig, J. C.
Venue
American Journal of Roentgenology
Published
2007-03
Volume
188
Issue
3
Pages
798-811
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2120570424
Cited by
185
References
0
FWCI
9.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative Accuracy of Renal Duplex Sonographic Parameters in the Diagnosis of Renal Artery Stenosis: Paired and Unpaired Analysis. https://app.cochat.ai/papers/10.2214/ajr.06.0355
The paper
Williams, G. J., Macaskill, P., Chan, S. F., Karplus, T. E., Yung, W., Hodson, E. M., & Craig, J. C. (2007). Comparative Accuracy of Renal Duplex Sonographic Parameters in the Diagnosis of Renal Artery Stenosis: Paired and Unpaired Analysis. American Journal of Roentgenology. https://doi.org/10.2214/ajr.06.0355

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.