Automatic Patient Centering for MDCT: Effect on Radiation Dose
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: The purpose of this study was to determine with phantom and patient imaging the effect of an automatic patient-centering technique on the radiation dose associated with MDCT. SUBJECTS AND METHODS: A 32-cm CT dose index (CTDI) phantom was scanned with 64-MDCT in three positions: gantry isocenter and 30 and 60 mm below the isocenter of the scanner gantry. In each position, surface, peripheral, and volume CTDIs were estimated with a standard 10-cm pencil ionization chamber. The institutional review board approved the study with 63 patients (36 men, 27 women; mean age, 51 years; age range, 22-83 years) undergoing chest (n = 18) or abdominal (n = 45) CT using the z-axis automatic exposure control technique. Each patient was positioned according to the region being scanned and then was centered in the gantry. Before scanning of a patient, automatic centering software was used to estimate patient off-centering and percentage of dose reduction with optimum recentering. Data were analyzed with linear correlation and the Student's t test. RESULTS: Peripheral and surface CTDIs increased approximately 12-18% with 30-mm off-center distance and 41-49% with 60-mm off-center distance. Approximately 95% (60/63) of patients were not positioned accurately in the gantry isocenter. The mean radiation dose saving with automatic centering of all patients was 13.0% +/- 0.9% (range, 2.6-29.9%). There was strong correlation between off-center distance and percentage of surface CTDI reduction with recentering of patients in the gantry isocenter (r2 = 0.85, p < 0.0001). CONCLUSION: Surfaces doses can be reduced if radiologic technologists can better center patients within the CT gantry. Automatic centering technique can help in optimum patient centering and result in as much as 30% reduction in surface dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shi, F., Wang, J., Shi, J., Wu, Z., Wang, Q., Tang, Z., He, K., Shi, Y., & Shen, D. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2987975 · Cited by 1,404
“In this case, AI is able to automate the process [17-25] by identifying the pose and shape of the patient from the data acquired with visual sensors such as RGB, Time-of-Flight (TOF) pressure imaging [26] or thermal (FIR) cameras.”
MethodHan, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Han, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Computed tomography in paediatric heart disease
Mortensen, K. H., & Tann, O. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20180201 · Cited by 24
Metadata
- Authors
- Li, J., Udayasankar, U. K., Toth, T. L., Seamans, J., Small, W. C., & Kalra, M. K.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2007-02
- Volume
- 188
- Issue
- 2
- Pages
- 547-552
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2034984742
- Cited by
- 206
- References
- 0
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Patient Centering for MDCT: Effect on Radiation Dose. https://app.cochat.ai/papers/10.2214/ajr.06.0370
- The paper
- Li, J., Udayasankar, U. K., Toth, T. L., Seamans, J., Small, W. C., & Kalra, M. K. (2007). Automatic Patient Centering for MDCT: Effect on Radiation Dose. American Journal of Roentgenology. https://doi.org/10.2214/ajr.06.0370
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.