Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Perioperative Endovascular Internal Iliac Artery Occlusion Balloon Placement in Management of Placenta Accreta

Tan, Cher Heng, Tay, Kiang Hiong, Sheah, Kenneth, Kwek, Kenneth, Wong, Kenneth, Tan, Hak Koon, Tan, Bien Soo · 2007 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of our study was to evaluate the efficacy of the perioperative placement of occlusion balloons within the internal iliac arteries in reducing intraoperative blood loss and transfusion requirements during cesarean delivery for women with placenta accreta or its variants. MATERIALS AND METHODS: Over a 30-month period, 11 patients with placenta accreta or its variants underwent cesarean delivery after bilateral internal iliac artery occlusion balloon placement (study group). The intraoperative blood loss and transfusion volumes, immediate postoperative change in hemoglobin levels, duration of surgery, and length of ICU stay and hospitalization of this study group were compared with 14 similar patients who underwent cesarean delivery without occlusion balloon placement over a 36-month period (control group). RESULTS: The mean intraoperative blood loss in the study group (2,011 mL; range, 400-5,000 mL) was 39.4% less than in the control group (3,316 mL; range, 1,000-4,000 mL) (p = 0.042). The mean volume of blood transfused was 52.1% less in the study group (1,058 mL; range, 0-3,600 mL) than in the control group (2,211 mL; range, 1,190-3,980 mL) (p = 0.005). There was no significant difference in the immediate postoperative change in hemoglobin levels (p = 0.44), length of hospitalization (p = 0.203), or ICU admission (p = 0.614). The duration of the surgery was significantly less in the study group (p = 0.046). CONCLUSION: Perioperative internal iliac artery occlusion balloon placement is a safe and minimally invasive technique that reduces intraoperative blood loss and transfusion requirements in patients with placenta accreta and its variants undergoing cesarean delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.07.2417

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 195

Metadata

Authors
Tan, C. H., Tay, K. H., Sheah, K., Kwek, K., Wong, K., Tan, H. K., & Tan, B. S.
Venue
American Journal of Roentgenology
Published
2007-11
Volume
189
Issue
5
Pages
1158-1163
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2126409933
Cited by
195
References
2
FWCI
5.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Perioperative Endovascular Internal Iliac Artery Occlusion Balloon Placement in Management of Placenta Accreta. https://app.cochat.ai/papers/10.2214/ajr.07.2417
The paper
Tan, C. H., Tay, K. H., Sheah, K., Kwek, K., Wong, K., Tan, H. K., & Tan, B. S. (2007). Perioperative Endovascular Internal Iliac Artery Occlusion Balloon Placement in Management of Placenta Accreta. American Journal of Roentgenology. https://doi.org/10.2214/ajr.07.2417

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.