Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

CT and PET: Early Prognostic Indicators of Response to Imatinib Mesylate in Patients with Gastrointestinal Stromal Tumor

Holdsworth, Clay H., Badawi, Ramsey D., Manola, Judith B., Kijewski, Marie F., Israel, David A., Demetri, George D., Van den Abbeele, Annick D. · 2007 · American Journal of Roentgenology

Abstract

OBJECTIVE: We report results from a pilot study aimed at optimizing the use of CT bidimensional measurements and 18F-FDG PET maximum standardized uptake values (SUVs-(max)) for determining response to prolonged imatinib mesylate treatment in patients with advanced gastrointestinal stromal tumors (GISTs). SUBJECTS AND METHODS: Sixty-three patients enrolled in a multicenter trial evaluating imatinib mesylate therapy for advanced GIST underwent FDG PET at baseline and 1 month after initiation of treatment. Of these 63 patients, 58 underwent concomitant CT. Time-to-treatment failure (TTF) was used as the outcome measure. Patients were followed up over a range of 23.7 to 37 months (median, 31.7 months). The predictive power of change in CT bidimensional measurements, change in PET SUVmax, and PET SUVmax at 1 month after initiation of treatment were determined, optimized, and compared. The effectiveness of combining metrics was also evaluated. RESULTS: Both a threshold PET SUVmax value of 2.5 at 1 month (p = 0.04) and the European Organization for Research and Treatment of Cancer (EORTC) criteria for partial response on FDG PET (25% reduction in PET SUVmax) at 1 month (p = 0.004) were predictive of prolonged treatment success. The Southwest Oncology Group (SWOG) criteria for partial response ((3) 50% reduction in CT bidimensional measurements) at 1 month were not predictive (p = 0.55) of TTF. Optimizing metrics improved results performance. An optimized PET SUVmax threshold of 3.4 (p = 0.00002), a reduction in the SUVmax of 40% (p = 0.002), and an optimized CT bidimensional measurement threshold--that is, no growth from baseline to 1 month (p = 0.00005)--outperformed the existing standards (i.e., EORTC and SWOG criteria). Combinations of metrics did not improve performance. CONCLUSION: The two best metrics were the optimized PET SUVmax threshold of 3.4 at 1 month (p = 0.00002) and the optimized CT bidimensional measurement threshold (no growth from baseline to 1 month, p = 0.00005) in this patient group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.07.2496

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 167

Metadata

Authors
Holdsworth, C. H., Badawi, R. D., Manola, J. B., Kijewski, M. F., Israel, D. A., Demetri, G. D., & Van den Abbeele, A. D.
Venue
American Journal of Roentgenology
Published
2007-12
Volume
189
Issue
6
Pages
W324-W330
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2039907242
Cited by
167
References
2
FWCI
16.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CT and PET: Early Prognostic Indicators of Response to Imatinib Mesylate in Patients with Gastrointestinal Stromal Tumor. https://app.cochat.ai/papers/10.2214/ajr.07.2496
The paper
Holdsworth, C. H., Badawi, R. D., Manola, J. B., Kijewski, M. F., Israel, D. A., Demetri, G. D., & Van den Abbeele, A. D. (2007). CT and PET: Early Prognostic Indicators of Response to Imatinib Mesylate in Patients with Gastrointestinal Stromal Tumor. American Journal of Roentgenology. https://doi.org/10.2214/ajr.07.2496

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.