CoChat

Comparison of Computer-Aided Detection to Double Reading of Screening Mammograms: Review of 231,221 Mammograms

Gromet, Matthew · 2008 · American Journal of Roentgenology
Cited by 144

The DOI matches its Crossref record.

Abstract

OBJECTIVE: This study compares the efficacy of single reading with computer-aided detection (CAD) to double reading and also to the first reader (without CAD) in a double-reading program. MATERIALS AND METHODS: A review was performed of 231,221 screening mammograms interpreted by experienced mammographers from 2001 through 2005 in a community-based mammography program. In 112,413 (48.6%), mammographers performed the first of two readings. In 118,808 (51.4%), they performed a single reading aided by CAD. RESULTS: For double reading, the first reader's recall rate was 10.2%; sensitivity, 81.4%; positive predictive value, as a percentage of positive screening mammograms resulting in a tissue diagnosis of cancer within 1 year (PPV(1)), 4.1%; and cancer detection rate, 4.12 per 1,000. After the double-reading process, the final recall rate was 11.9%; sensitivity, 88.0%; PPV(1), 3.7%; and cancer detection rate, 4.46 per 1,000. For single-reading with CAD, the recall rate was 10.6%; sensitivity, 90.4%; PPV(1), 3.9%; and cancer detection rate, 4.20 per 1,000. Statistically significant results included a lower recall rate with CAD compared with double reading (10.6% vs 11.9%, respectively; p < 0.0001); increased sensitivity with CAD compared with the first reader (90.4% vs 81.4%, p < 0.0001); and increased recall rate with CAD compared with the first reader (10.6% vs 10.2%, p < 0.0001). CONCLUSION: Double reading increased sensitivity with a modest increase in the recall rate compared with single reading. Single reading with CAD, compared with double reading, resulted in a small, but not statistically significant, increase in sensitivity with a lower recall rate. Our results indicate that CAD enhances performance of a single reader, yielding increased sensitivity with only a small increase in recall rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.07.2812

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 144

Metadata

Authors
Gromet, M.
Venue
American Journal of Roentgenology
Published
2008-04
Volume
190
Issue
4
Pages
854-859
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2012010855
Cited by
144
References
0
FWCI
14.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Computer-Aided Detection to Double Reading of Screening Mammograms: Review of 231,221 Mammograms. https://app.cochat.ai/papers/10.2214/ajr.07.2812
The paper
Gromet, M. (2008). Comparison of Computer-Aided Detection to Double Reading of Screening Mammograms: Review of 231,221 Mammograms. American Journal of Roentgenology. https://doi.org/10.2214/ajr.07.2812

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.