The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Feasibility of In Vivo MR Elastographic Splenic Stiffness Measurements in the Assessment of Portal Hypertension
Open accessAbstract
OBJECTIVE: Liver stiffness is associated with portal hypertension in patients with chronic liver disease. However, the relation between spleen stiffness and clinically significant portal hypertension remains unknown. The purposes of this study were to determine the feasibility of measuring spleen stiffness with MR elastography and to prospectively test the technique in healthy volunteers and in patients with compensated liver disease. MATERIALS AND METHODS: Spleen stiffness was measured with MR elastography in 12 healthy volunteers (mean age, 37 years; range, 25-82 years) and 38 patients (mean age, 56 years; range, 36-60 years) with chronic liver disease of various causes. For patients with liver disease, laboratory findings, spleen size, presence and size of esophageal varices, and liver histologic results were recorded. Statistical analyses were performed to assess all measurements. RESULTS: MR elastography of the spleen was successfully performed on all volunteers and patients. The mean spleen stiffness was significantly lower in the volunteers (mean, 3.6 +/- 0.3 kPa) than in the patients with liver fibrosis (mean, 5.6 +/- 5.0 kPa; range, 2.7-19.2 kPa; p < 0.001). In addition, a significant correlation was observed between liver stiffness and spleen stiffness for the entire cohort (r(2) = 0.75; p < 0.001). Predictors of spleen stiffness were splenomegaly, spleen volume, and platelet count. A mean spleen stiffness of 10.5 kPa or greater was identified in all patients with esophageal varices. CONCLUSION: MR elastography of the spleen is feasible and shows promise as a quantitative method for predicting the presence of esophageal varices in patients with advanced hepatic fibrosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonalcoholic Steatohepatitis: A Proposal for Grading and Staging The Histological Lesions
Brunt, E. M., Janney, C. G., Di Bisceglie, A. M., Neuschwander-Tetri, B. A., & Bacon, B. R. (1999) · American Journal of Gastroenterology · doi:10.1111/j.1572-0241.1999.01377.x · Cited by 3,907
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Self-citationSilveira, M. G., Brunt, E. M., Heathcote, J., Gores, G. J., Lindor, K. D., & Mayo, M. J. (2010) · Hepatology · doi:10.1002/hep.23637 · Cited by 87
Cited by
Mack, C. L., Adams, D., Assis, D. N., Kerkar, N., Manns, M. P., Mayo, M. J., Vierling, J. M., Alsawas, M., Murad, M. H., & Czaja, A. J. (2020) · Hepatology · doi:10.1002/hep.31065 · Cited by 983
“(266-269) Furthermore, MRE assessment of splenic stiffness can have prognostic value for predicting portal hypertension and esophageal varices.(270) In AIH, the accuracy (97%), sensitivity (90%), specificity (100%), positive predictive value (100%), and negative predictive value (90%) of MRE for advanced hepatic fibro…”
BackgroundUltrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
Liver stiffness: a novel parameter for the diagnosis of liver disease
Mueller, S. (2010) · Hepatic Medicine: Evidence and Research · doi:10.2147/hmer.s7394 · Cited by 434
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Metadata
- Authors
- Talwalkar, J. A., Yin, M., Venkatesh, S., Rossman, P. J., Grimm, R. C., Manduca, A., Romano, A., Kamath, P. S., & Ehman, R. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2009-07
- Volume
- 193
- Issue
- 1
- Pages
- 122-127
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1989245785
- Cited by
- 198
- References
- 3
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.