Whole-Body MRI Versus PET in Assessment of Multiple Myeloma Disease Activity
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma. SUBJECTS AND METHODS: Twenty-four patients (13 women, 11 men; mean age, 67.1 years; range, 44-83 years) with bone marrow biopsy-proven multiple myeloma were included in the study. All patients underwent PET/CT and whole-body MRI within 10 days of each other. Eight patients underwent more than one follow-up PET/CT and whole-body MRI examination, for a total of 34 pairs of images. Activity was defined as lesions with a maximum standardized uptake value greater than 2.5 at PET and as evidence of marrow packing at whole-body MRI. PET and whole-body MRI results were correlated with findings at bone marrow aspiration biopsy. RESULTS: PET had a sensitivity of 59%, specificity of 75%, positive predictive value of 81%, and negative predictive value of 50% (p = 0.08). Whole-body MRI had a sensitivity of 68%, specificity of 83%, positive predictive value of 88%, and negative predictive value of 59% (p = 0.01). In 62% of cases, PET and whole-body MRI findings were concordant. When PET and whole-body MRI findings were concordant and positive, no false-positive results were found, yielding a specificity and a positive predictive value of 100% (p = 0.04). CONCLUSION: Whole-body MRI performed better than PET in the assessment of disease activity, having a higher sensitivity and specificity. The positive predictive value of whole-body MRI in the assessment of active disease was high at 88%. When used in combination and with concordant findings, PET and whole-body MRI were found to have a specificity and positive predictive value of 100%, which may be of value to clinicians assessing the effectiveness of aggressive and expensive treatment regimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Global Cancer Statistics, 2002
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.2.74 · Cited by 18,196
Review of 1027 Patients With Newly Diagnosed Multiple Myeloma
Kyle, R. A., Gertz, M. A., Witzig, T. E., Lust, J. A., Lacy, M. Q., Dispenzieri, A., Fonseca, R., Rajkumar, S. V., Offord, J. R., Larson, D. R., et al. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.1.21 · Cited by 2,447 · cited 1×
“Multiple myeloma has high mortality and morbidity, patients often experiencing weight loss, fatigue, bone pain, and recurrent infections [2].”
BackgroundWhole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
Antoch, G. (2003) · JAMA · doi:10.1001/jama.290.24.3199 · Cited by 551
Zamagni, E., Nanni, C., Patriarca, F., Englaro, E., Castellucci, P., Geatti, O., Tosi, P., Tacchetti, P., Cangini, D., Perrone, G., et al. (2007) · Haematologica · doi:10.3324/haematol.10554 · Cited by 354
Durie, B. G. M. (2006) · European Journal of Cancer · doi:10.1016/j.ejca.2005.11.037 · Cited by 300 · cited 1×
“which the skeletal survey was the only radiologic criterion, has been updated as the DurieSalmon plus staging system, which integrates MRI, CT, and PET information [19].”
BackgroundCombined PET/CT Imaging in Oncology Impact on Patient Management
Kluetz, P. (2000) · Clinical Positron Imaging · doi:10.1016/s1095-0397(01)00055-3 · Cited by 226 · cited 1×
“Results of some studies suggest that PET/CT is more costeffective than other techniques, obviating multiple investigations [29, 30].”
BackgroundSilberstein, M. J., Sundaram, M., de Mello, D., & McGuire, M. H. (1984) · Orthopedics · doi:10.3928/0147-7447-19840201-18 · Cited by 178
Initial results in the assessment of multiple myeloma using 18F-FDG PET
Schirrmeister, H., Bommer, M., Buck, A., Müller, S., Messer, P., Bunjes, D., Döhner, H., Bergmann, L., & Reske, S. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0711-3 · Cited by 174 · cited 3×
“reported [4, 11, 21].”
BackgroundCurrent Concepts in the Evaluation of Multiple Myeloma with MR Imaging and FDG PET/CT
Hanrahan, C. J., Christensen, C. R., & Crim, J. R. (2010) · Radiographics · doi:10.1148/rg.301095066 · Cited by 164
Skeletal survey in advanced multiple myeloma: radiographic versus MR imaging survey
Lecouvet, F. E., Malghem, J., Michaux, L., Maldague, B., Ferrant, A., Michaux, J., & Vande Berg, B. C. (1999) · British Journal of Haematology · doi:10.1046/j.1365-2141.1999.01529.x · Cited by 159 · cited 1×
“The sensitivity of whole-body MRI in other studies ranges from 70% to 89% depending on the stage of disease [17, 23, 24].”
BackgroundGuidelines for the use of imaging in the management of myeloma
D’Sa, S., Abildgaard, N., Tighe, J. E., Shaw, P. J., & Hall-Craggs, M. A. (2007) · British Journal of Haematology · doi:10.1111/j.1365-2141.2007.06491.x · Cited by 116 · cited 2×
“In the assessment of response to therapy, the guidelines do not include other techniques as routine but acknowledge their potential role in selected cases [3].”
BackgroundMethodMultiple Myeloma Treatment Response Assessment with Whole-Body Dynamic Contrast-enhanced MR Imaging
Lin, C., Luciani, A., Belhadj, K., Deux, J., Kuhnowski, F., Maâtouk, M., Beaussart, P., Cuénod, C. A., Haïoun, C., & Rahmouni, A. (2010) · Radiology · doi:10.1148/radiol.09090629 · Cited by 95
Epidemiology and outcomes research for MGUS, myeloma and amyloidosis
Sirohi, B., & Powles, R. (2006) · European Journal of Cancer · doi:10.1016/j.ejca.2006.01.065 · Cited by 74 · cited 1×
“1 years [20].”
Fechtner, K., Hillengaß, J., Delorme, S., Heiß, C., Neben, K., Goldschmidt, H., Kauczor, H., & Weber, M. D. (2010) · Radiology · doi:10.1148/radiol.10091809 · Cited by 67
van Agthoven, M., Segeren, C. M., Buijt, I., Groot, C. A. U., van der Holt, B., Lokhorst, H. M., & Sonneveld, P. (2004) · European Journal of Cancer · doi:10.1016/j.ejca.2004.01.019 · Cited by 59 · cited 1×
“Although PET/CT is relatively expensive, it is considerably less expensive, at an average cost in the United States of $1,900 [25], than bortezomib, six cycles of which cost $25,000– $28,000 (Millennium Pharmaceuticals, Velcade [bortezomib] for injection prescribing information, 2003), and autologous stem cell transpl…”
BackgroundKostenüberlegungen zur Ganzkörper-MRT und PET-CT im Rahmen des onkologischen Stagings
Plathow, C., Walz, M., Lichy, M. P., Aschoff, P., Pfannenberg, C., Bock, H., Eschmann, S. M., Claussen, C. D., & Schlemmer, H.-P. (2007) · Der Radiologe · doi:10.1007/s00117-007-1547-z · Cited by 57
The role of magnetic resonance imaging in oncology
Hernando, C. G., Esteban, L., Cañas, T., den Brule, E. V., & Pastrana, M. (2010) · Clinical & Translational Oncology · doi:10.1007/s12094-010-0565-x · Cited by 50
Weininger, M., Lauterbach, B., Knop, S. T., Pabst, T., Kenn, W., Hahn, D., & Beissert, M. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.10.025 · Cited by 46
Whole body MR imaging: Applications in oncology
Johnston, C., Brennan, S., Ford, S., & Eustace, S. J. (2006) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2005.09.018 · Cited by 42 · cited 1×
“Conventional and whole-body MRI techniques in the evaluation of multiple myeloma are well established [7, 12–17].”
MethodSelf-citationMishra, V., Andresen, S., Brinch, L., Kvaløy, S., Ernst, P., Lønset, M. K., Tangen, J., Wikelund, J., Flatum, C., Baggerød, E., et al. (2005) · Bone Marrow Transplantation · doi:10.1038/sj.bmt.1704988 · Cited by 36 · cited 1×
“Although PET/CT is relatively expensive, it is considerably less expensive, at an average cost in the United States of $1,900 [25], than bortezomib, six cycles of which cost $25,000– $28,000 (Millennium Pharmaceuticals, Velcade [bortezomib] for injection prescribing information, 2003), and autologous stem cell transpl…”
BackgroundTen Years of Improvement in the Management of Multiple Myeloma: 2000-2010
Harousseau, J. (2010) · Clinical Lymphoma Myeloma & Leukemia · doi:10.3816/clml.2010.n.076 · Cited by 36
PET/CT in primary musculoskeletal tumours: a step forward
Lakkaraju, A., Patel, C. N., Bradley, K. M., & Scarsbrook, A. F. (2010) · European Radiology · doi:10.1007/s00330-010-1862-z · Cited by 32
Ak, İ., & Gülbaş, Z. (2010) · Annals of Hematology · doi:10.1007/s00277-010-1037-7 · Cited by 28
Wislöff, F., Gulbrandsen, N., & Nord, E. (1999) · PharmacoEconomics · doi:10.2165/00019053-199916040-00002 · Cited by 21
18F-FDG-PET and PET/CT for Evaluating Primary Bone Tumors
Mittra, E., & Iagaru, A. H. (2010) · PET Clinics · doi:10.1016/j.cpet.2010.04.004 · Cited by 6
Durie, B. G. M., & Salmon, S. E. (1975) · Cancer · doi:10.1002/1097-0142(197509)36:3<842::aid-cncr2820360303>3.0.co;2-u · cited 1×
“The previously widely accepted Durie-Salmon staging system [18], established in 1975, in Whole-Body MRI Versus PET in Assessment of Multiple Myeloma Disease Activity”
Method
Cited by
Kumar, S., Paiva, B., Anderson, K. C., Durie, B., Landgren, O., Moreau, P., Munshi, N., Lonial, S., Bladé, J., Mateos, M.-V., et al. (2016) · The Lancet Oncology · doi:10.1016/s1470-2045(16)30206-6 · Cited by 3,061
Cavo, M., Terpos, E., Nanni, C., Moreau, P., Lentzsch, S., Zweegman, S., Hillengass, J., Engelhardt, M., Usmani, S. Z., Vesole, D. H., et al. (2017) · The Lancet Oncology · doi:10.1016/s1470-2045(17)30189-4 · Cited by 544
In vivo imaging of glucose uptake and metabolism in tumors
Walker-Samuel, S., Ramasawmy, R., Torrealdea, F., Rega, M., Rajkumar, V., Johnson, S. P., Richardson, S., Gonçalves, M., Parkes, H. G., Årstad, E., et al. (2013) · Nature Medicine · doi:10.1038/nm.3252 · Cited by 479
“We maintained the orientation of the tumor and, following excision, tumors were snap-frozen using liquid nitrogen-cooled isopentane and cut in half along the longest axial diameter, corresponding to the MRI imaging slice.”
Influential
Metadata
- Authors
- Shortt, C. P., Gleeson, T. G., Breen, K. A., McHugh, J., O'Connell, M. J., O'Gorman, P. J., & Eustace, S. J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2009-04
- Volume
- 192
- Issue
- 4
- Pages
- 980-986
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2162203216
- Cited by
- 184
- References
- 27
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.