Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 195

The DOI matches its Crossref record.

Real-Time Sonoelastography Findings in Healthy Achilles Tendons

De Zordo, Tobias, Fink, Christian, Feuchtner, Gudrun M., Smekal, Vinzenz, Reindl, Markus, Klauser, Andrea Sabine · 2009 · American Journal of Roentgenology

Abstract

OBJECTIVE: Real-time sonoelastography is a new ultrasound-based technique able to assess tissue elasticity that has already shown feasibility in tumor diagnosis. The aim of this study was to assess the performance of real-time sonoelastography in depicting the Achilles tendons of healthy volunteers and to compare sonoelastography findings with conventional ultrasound findings. MATERIALS AND METHODS: Eighty asymptomatic Achilles tendons of 40 healthy volunteers (19 men, 21 women; mean age, 38 years; range, 20-76 years) were examined on real-time sonoelastography and ultrasound. The Achilles tendons were divided into the following thirds for image evaluation: proximal (musculotendinous junction), middle (2-6 cm above insertion at the calcaneus), and distal (insertion at the calcaneus). Longitudinal and axial images of each tendon third were obtained using ultrasound and real-time sonoelastography. Real-time sonoelastography images were evaluated by reviewers using an experimentally proven color grading system. RESULTS: The Achilles tendons showed mainly a hard structured pattern (86.7%) (208/240 tendon thirds) on sonoelastography; however, mild softening was found in 12.1% (29/240) of the tendons. Distinct softening corresponding to alterations found also on ultrasound and, therefore, suggesting subclinical changes was detected in 1.3% (3/240). The overall correlation (kappa) between real-time sonoelastography and ultrasound findings was 1.00. CONCLUSION: In healthy volunteers, the Achilles tendon appeared hard on real-time sonoelastography with excellent correlation to ultrasound. Further investigation including pathologic tendons should be performed to prove the value of real-time sonoelastography in the assessment of Achilles tendinopathy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.08.1843

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
De Zordo, T., Fink, C., Feuchtner, G. M., Smekal, V., Reindl, M., & Klauser, A. S.
Venue
American Journal of Roentgenology
Published
2009-08
Volume
193
Issue
2
Pages
W134-W138
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2005830633
Cited by
195
References
0
FWCI
7.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Sonoelastography Findings in Healthy Achilles Tendons. https://app.cochat.ai/papers/10.2214/ajr.08.1843
The paper
De Zordo, T., Fink, C., Feuchtner, G. M., Smekal, V., Reindl, M., & Klauser, A. S. (2009). Real-Time Sonoelastography Findings in Healthy Achilles Tendons. American Journal of Roentgenology. https://doi.org/10.2214/ajr.08.1843

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.