Effect of Padding Duration on Radiation Dose and Image Interpretation in Prospectively ECG-Triggered Coronary CT Angiography
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Prospectively ECG-triggered coronary CT angiography images are acquired during a window in middiastole. Additional surrounding x-ray beam on time, or padding, can be variably set, and the increased padding results in additional available phases for analysis. The purpose of this study was to assess the effect of padding duration on image interpretability and its incident effect on radiation dose. SUBJECTS AND METHODS: We prospectively evaluated imaging of 886 patients undergoing consecutive prospectively ECG-triggered coronary CT angiographic examinations at three centers and compared the findings in patients stratified by padding duration. We assessed the effect of padding duration on image interpretability and radiation dose. RESULTS: The mean patient age was 56 +/- 12 years, and 58% of the patients were men. The median heart rate was 55 beats/min (interquartile range, 50-61 beats/min). Padding duration was 0, 1-99, and 100-150 milliseconds for 268, 482, and 136 patients, respectively, with no difference in image interpretability rate between groups (per patient, 98.8%, 97.3%, and 97.1%; per artery, 99.2%, 99.2%, and 99.1%). The groups differed in median radiation dose (2.3 mSv [interquartile range, 1.5-3.2 mSv]; 3.8 mSv [interquartile range, 2.3-4.7 mSv]; 5.5 mSv [interquartile range, 3.8-6.1 mSv]; p < 0.001). Independent of patient and scan parameters, increased padding was associated with greater radiation dose (45% increase per 100-millisecond increase in padding, p < 0.001). CONCLUSION: In a large multicenter study of coronary CT angiography of patients with excellent heart rate control, the use of minimal padding was associated with a substantial reduction in radiation dose with preserved image interpretability. Use of no or reduced padding should be considered in dose-reduction strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Self-citationHan, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Self-citationComputed tomography in paediatric heart disease
Mortensen, K. H., & Tann, O. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20180201 · Cited by 24
Complex adult congenital heart disease on cross-sectional imaging: an introductory overview
Saleh, M., Gendy, D., Voges, I., Nyktari, E., & Arzanauskaite, M. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01201-y · Cited by 7
“However, methods such as padding, also known as additional surrounding X-ray beam on time, can compensate for a high heart rate and variability [29].”
Method
Metadata
- Authors
- LaBounty, T. M., Leipsic, J., Min, J. K., Heilbron, B., Mancini, G. B. J., Lin, F. Y., & Earls, J. P.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2010-04
- Volume
- 194
- Issue
- 4
- Pages
- 933-937
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2050608568
- Cited by
- 66
- References
- 0
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Padding Duration on Radiation Dose and Image Interpretation in Prospectively ECG-Triggered Coronary CT Angiography. https://app.cochat.ai/papers/10.2214/ajr.09.3371
- The paper
- LaBounty, T. M., Leipsic, J., Min, J. K., Heilbron, B., Mancini, G. B. J., Lin, F. Y., & Earls, J. P. (2010). Effect of Padding Duration on Radiation Dose and Image Interpretation in Prospectively ECG-Triggered Coronary CT Angiography. American Journal of Roentgenology. https://doi.org/10.2214/ajr.09.3371
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.