CoChat

Effect of Padding Duration on Radiation Dose and Image Interpretation in Prospectively ECG-Triggered Coronary CT Angiography

LaBounty, Troy M., Leipsic, Jonathon, Min, James K., Heilbron, Brett, Mancini, G. B. John, Lin, Fay Y., Earls, James P. · 2010 · American Journal of Roentgenology
Cited by 66

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Prospectively ECG-triggered coronary CT angiography images are acquired during a window in middiastole. Additional surrounding x-ray beam on time, or padding, can be variably set, and the increased padding results in additional available phases for analysis. The purpose of this study was to assess the effect of padding duration on image interpretability and its incident effect on radiation dose. SUBJECTS AND METHODS: We prospectively evaluated imaging of 886 patients undergoing consecutive prospectively ECG-triggered coronary CT angiographic examinations at three centers and compared the findings in patients stratified by padding duration. We assessed the effect of padding duration on image interpretability and radiation dose. RESULTS: The mean patient age was 56 +/- 12 years, and 58% of the patients were men. The median heart rate was 55 beats/min (interquartile range, 50-61 beats/min). Padding duration was 0, 1-99, and 100-150 milliseconds for 268, 482, and 136 patients, respectively, with no difference in image interpretability rate between groups (per patient, 98.8%, 97.3%, and 97.1%; per artery, 99.2%, 99.2%, and 99.1%). The groups differed in median radiation dose (2.3 mSv [interquartile range, 1.5-3.2 mSv]; 3.8 mSv [interquartile range, 2.3-4.7 mSv]; 5.5 mSv [interquartile range, 3.8-6.1 mSv]; p < 0.001). Independent of patient and scan parameters, increased padding was associated with greater radiation dose (45% increase per 100-millisecond increase in padding, p < 0.001). CONCLUSION: In a large multicenter study of coronary CT angiography of patients with excellent heart rate control, the use of minimal padding was associated with a substantial reduction in radiation dose with preserved image interpretability. Use of no or reduced padding should be considered in dose-reduction strategies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.09.3371

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 66

Metadata

Authors
LaBounty, T. M., Leipsic, J., Min, J. K., Heilbron, B., Mancini, G. B. J., Lin, F. Y., & Earls, J. P.
Venue
American Journal of Roentgenology
Published
2010-04
Volume
194
Issue
4
Pages
933-937
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2050608568
Cited by
66
References
0
FWCI
8.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Padding Duration on Radiation Dose and Image Interpretation in Prospectively ECG-Triggered Coronary CT Angiography. https://app.cochat.ai/papers/10.2214/ajr.09.3371
The paper
LaBounty, T. M., Leipsic, J., Min, J. K., Heilbron, B., Mancini, G. B. J., Lin, F. Y., & Earls, J. P. (2010). Effect of Padding Duration on Radiation Dose and Image Interpretation in Prospectively ECG-Triggered Coronary CT Angiography. American Journal of Roentgenology. https://doi.org/10.2214/ajr.09.3371

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.