The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Estimating Effective Dose for CT Using Dose–Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning
Abstract
OBJECTIVE: The objective of our study was to compare dose-length product (DLP)-based estimates of effective dose with organ dose-based calculations using tissue-weighting factors from publication 103 of the International Commission on Radiological Protection (ICRP) or dual-energy CT protocols. MATERIALS AND METHODS: Using scanner- and energy-dependent organ dose coefficients, we calculated effective doses for CT examinations of the head, chest, coronary arteries, liver, and abdomen and pelvis using routine clinical single- or dual-energy protocols and tissue-weighting factors published in 1991 in ICRP publication 60 and in 2007 in ICRP publication 103. Effective doses were also generated from the respective DLPs using published conversion coefficients that depend only on body region. For each examination type, the same volume CT dose index was used for single- and dual-energy scans. RESULTS: Effective doses calculated for CT examinations using organ dose estimates and ICRP 103 tissue-weighting factors differed relative to ICRP 60 values by -39% (-0.5 mSv, head), 14% (1 mSv, chest), 36% (4 mSv, coronary artery), 4% (0.6 mSv, liver), and -7% (-1 mSv, abdomen and pelvis). DLP-based estimates of effective dose, which were derived using ICRP 60-based conversion coefficients, were less than organ dose-based estimates for ICRP 60 by 4% (head), 23% (chest), 37% (coronary artery), 12% (liver), and 19% (abdomen and pelvis) and for ICRP 103 by -34% (head), 37% (chest), 74% (coronary artery), 16% (liver), and 12% (abdomen and pelvis). All results were energy independent. CONCLUSION: These differences in estimates of effective dose suggest the need to reassess DLP to E conversion coefficients when adopting ICRP 103, particularly for scans over the breast. For the evaluated scanner, DLP to E conversion coefficients were energy independent, but ICRP 60-based conversion coefficients underestimated effective dose relative to organ dose-based calculations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,154
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · RadioGraphics · doi:10.1148/rg.262055138 · Cited by 768
Self-citationWs, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
CT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
Self-citationA method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Effective dose: how should it be applied to medical exposures?
Martin, C. J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/25922439 · Cited by 377
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Self-citationPerformance Evaluation of a 64-Slice CT System with z-Flying Focal Spot
Flohr, T., Stierstorfer, K., Raupach, R., Ulzheimer, S., & Bruder, H. (2004) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2004-813717 · Cited by 255
Dosimetry for optimisation of patient protection in computed tomography
Jessen, K. A., Shrimpton, P. C., Geleijns, J., Panzer, W., & Tosi, G. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00024-4 · Cited by 187
How Effective Is Effective Dose as a Predictor of Radiation Risk?
McCollough, C. H., Christner, J. A., & Kofler, J. M. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4179 · Cited by 169
Self-citationMathematical phantoms representing children of various ages for use in estimates of internal dose
Cristy, M. (1980) · doi:10.2172/5308345 · Cited by 167
Patient‐specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
Li, X., Samei, E., Segars, W. P., Sturgeon, G. M., Colsher, J. G., Toncheva, G. I., Yoshizumi, T. T., & Frush, D. P. (2010) · Medical Physics · doi:10.1118/1.3515864 · Cited by 156
Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
Li, X., Samei, E., Segars, W. P., Sturgeon, G. M., Colsher, J. G., & Frush, D. P. (2011) · Radiology · doi:10.1148/radiol.11101900 · Cited by 116
Computed Tomography Dose Assessment - A Practical Approach
Leitz, W., Axelsson, B., & Szendrö, G. (1995) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a082564 · Cited by 114
CT DOSE: HOW TO MEASURE, HOW TO REDUCE
McCollough, C. H. (2008) · Health Physics · doi:10.1097/01.hp.0000326343.35884.03 · Cited by 95
Self-citationPatient Dose in Cardiac Computed Tomography
McCollough, C. H. (2003) · Herz · doi:10.1007/s00059-003-2447-2 · Cited by 89
Self-citationCardiac imaging: does radiation matter?
Einstein, A. J., & Knuuti, J. M. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr281 · Cited by 74
Kim, S. Y., Lee, K. H., Kim, K., Kim, T., Lee, H. S., Hwang, S.-S., Song, K., Kang, H. S., Kim, Y. H., & Rhee, J. E. (2011) · Radiology · doi:10.1148/radiol.11102247 · Cited by 69
Bankier, A. A., & Tack, D. (2010) · Journal of Thoracic Imaging · doi:10.1097/rti.0b013e3181eebc49 · Cited by 61
Zanca, F., Demeter, M., Oyen, R., & Bosmans, H. (2011) · European Radiology · doi:10.1007/s00330-011-2332-y · Cited by 53
A pediatric CT dose and risk estimator
Alessio, A. M., & Phillips, G. S. (2010) · Pediatric Radiology · doi:10.1007/s00247-010-1761-0 · Cited by 42
Hosch, W., Heye, T. J., Schulz, F., Lehrke, S., Schlieter, M., Giannitsis, E., Kauczor, H., Katus, H. A., & Korosoglou, G. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.07.011 · Cited by 31
Papadakis, A. E., Perisinakis, K., Oikonomou, I., & Damilakis, J. E. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3182213c55 · Cited by 29
Point/counterpoint: dose-related issues in cardiac CT imaging
Newman, B., & Vasanawala, S. S. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2153-9 · Cited by 8
Cited by
CT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
Self-citationICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Picano, E., Vano, E., Rehani, M. M., Cuocolo, A., Mont, L., Bodi, V., Bar, O., Maccia, C., Pierard, L., Sicari, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht394 · Cited by 361
NCCN Guidelines Insights: Kidney Cancer, Version 2.2020
Motzer, R. J., Jonasch, E., Michaelson, M. D., Nandagopal, L., Gore, J. L., George, S., Alva, A., Haas, N., Harrison, M. R., Plimack, E. R., et al. (2019) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2019.0054 · Cited by 287
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Metadata
- Authors
- Christner, J. A., Kofler, J. M., & McCollough, C. H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2010-04
- Volume
- 194
- Issue
- 4
- Pages
- 881-889
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2043654907
- Cited by
- 492
- References
- 28
- FWCI
- 24.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.