The DOI matches its Crossref record.
A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
Abstract
OBJECTIVE: The purpose of this study was to compare the subjective image quality, image noise, and radiation dose of chest CT images reconstructed with a 30% blend of iterative reconstruction and 70% conventional filtered back projection (FBP) with those of images generated with 100% FBP. SUBJECTS AND METHODS: Clinically indicated chest CT examinations of 292 consecutively registered patients were prospectively alternately assigned to two scanners on which different reconstruction techniques were used: adaptive statistical iterative reconstruction (ASIR) blended with FBP and 100% FBP. Both acquisitions were performed with dose modulation (noise index, 25 for ASIR and 21 for FBP). Patient demographics and habitus were recorded. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 3-point Likert scale and measured image noise and radiation dose. RESULTS: Compared with FBP images, ASIR images had significantly lower subjective image quality (p = 0.01), less image noise (p = 0.02), and less radiation dose (p < 0.0001). The CT dose index of the ASIR cohort (11.3 ± 51) was significantly lower than that of the 100% FBP cohort (15.4 ± 6.3) (p < 0.0001). Interobserver agreement on subjective image quality was excellent for both ASIR and FBP (Cronbach α, 0.92, p < 0.0001; Cronbach α, 0.85, p < 0.0001). CONCLUSION: In clinically indicated chest CT examinations, ASIR images had better image quality and less image noise at a lower radiation dose than images acquired with a conventional FBP reconstruction algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Self-citationIterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Katsura, M., Matsuda, I., Akahane, M., Sato, J., Akai, H., Yasaka, K., Kunimatsu, A., & Ohtomo, K. (2012) · European Radiology · doi:10.1007/s00330-012-2452-z · Cited by 278
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Metadata
- Authors
- Leipsic, J., Nguyen, G., Brown, J., Sin, D., & Mayo, J. R.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2010-11
- Volume
- 195
- Issue
- 5
- Pages
- 1095-1099
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1997833915
- Cited by
- 221
- References
- 0
- FWCI
- 22.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.