The DOI matches its Crossref record.
Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses
Abstract
OBJECTIVE: The purpose of this study was to validate the utility of dual-source dual-energy MDCT in quantifying iodine concentration in a phantom and in renal masses. MATERIALS AND METHODS: A series of tubes containing solutions of varying iodine concentration were imaged with dual-source dual-energy MDCT. Iodine concentration was calculated and compared with known iodine concentration. Single-phase contrast-enhanced dual-source dual-energy MDCT data on 15 patients with renal lesions then were assessed independently by two readers. Dual-energy postprocessing was used to generate iodine-only images. Regions of interest were placed on the iodine image over the lesion and, as a reference, over the aorta, for recording of iodine concentration in the lesion and in the aorta. Another radiologist determined lesion enhancement by comparing truly unenhanced with contrast-enhanced images. Mixed-model analysis of variance based on ranks was used to compare lesion types (simple cyst, hemorrhagic cyst, enhancing mass) in terms of lesion iodine concentration and lesion-to-aorta iodine ratio. RESULTS: In the phantom study, there was excellent correlation between calculated and true iodine concentration (R(2) = 0.998, p < 0.0001). In the patient study, 13 nonenhancing (10 simple and three hyperdense cysts) and eight enhancing renal masses were evaluated in 15 patients. The lesion iodine concentration and lesion-to-aorta iodine ratio in enhancing masses were significantly higher than in hyperdense and simple cysts (p < 0.0001). CONCLUSION: Iodine quantification with dual-source dual-energy MDCT is accurate in a phantom and can be used to determine the presence and concentration of iodine in a renal lesion. Characterization of renal masses may be possible with a single dual-source dual-energy MDCT acquisition without unenhanced images or reliance on a change in attenuation measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
HANDSCHUH, S., BEISSER, C. J., RUTHENSTEINER, B., & METSCHER, B. D. (2017) · Journal of Microscopy · doi:10.1111/jmi.12543 · Cited by 48
“…contrast can be achieved between body tissues and heavy atoms of contrast materials; especially iodine, now a well-established contrast agent for CT, has optimal spectral properties for DECT (Nakayama et al., 2005; Kang et al., 2010; Chandarana et al., 2011; Johnson, 2012; Li et al., 2013).”
Metadata
- Authors
- Chandarana, H., Megibow, A. J., Cohen, B. A., Srinivasan, R., Kim, D., Leidecker, C., & Macari, M.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2011-06
- Volume
- 196
- Issue
- 6
- Pages
- W693-W700
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2164210934
- Cited by
- 229
- References
- 0
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses. https://app.cochat.ai/papers/10.2214/ajr.10.5541
- The paper
- Chandarana, H., Megibow, A. J., Cohen, B. A., Srinivasan, R., Kim, D., Leidecker, C., & Macari, M. (2011). Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses. American Journal of Roentgenology. https://doi.org/10.2214/ajr.10.5541
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.