CoChat

CT Perfusion in Oncologic Imaging: A Useful Tool?

Open access
García-Figueiras, Roberto, Goh, Vicky J., Padhani, Anwar R., Baleato-González, Sandra, Garrido, Miguel, León, Luis, Gómez-Caamaño, Antonio · 2013 · American Journal of Roentgenology
Cited by 175

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: This article summarizes the current status of CT perfusion in oncologic imaging, including lesion characterization, staging, prediction of patient outcome or response to therapy, assessment of response to different therapies, and evaluation of tumor relapse. Technical limitations and drawbacks of CT perfusion are also discussed. CONCLUSION: Tumor angiogenesis is essential for cancer growth and provides an attractive target for oncologic therapies. CT perfusion is an emerging imaging tool that provides both qualitative and quantitative information regarding tumor angiogenesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.11.8476

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
García-Figueiras, R., Goh, V. J., Padhani, A. R., Baleato-González, S., Garrido, M., León, L., & Gómez-Caamaño, A.
Venue
American Journal of Roentgenology
Published
2013-01
Volume
200
Issue
1
Pages
8-19
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2119519779
Cited by
175
References
5
FWCI
9.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.