Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 398

The DOI matches its Crossref record.

MECHANICAL DEVICES FOR ARTERIAL OCCLUSION

Open access
GIANTURCO, C., ANDERSON, J. H., WALLACE, S.·1975·American Journal of Roentgenology

Abstract

Two mechanical devices for the purpose of occluding vessels are presented. Cotton tails, small metallic segments with attached cotton threads, will effectively occlude small arteries of approximately 2 mm. in diameter. Wool coils, 5 cm. segments of the outer portion of steel guidewires with attached wool strands, obstructed major vessels just beyond the tip of the catheter. The use of these devices has been investigated in dogs and then applied clinically in the occlusion of renal arteries in patients with hypernephroma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.124.3.428

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 398

Metadata

Authors
GIANTURCO, C., ANDERSON, J. H., & WALLACE, S.
Venue
American Journal of Roentgenology
Published
1975-07
Volume
124
Issue
3
Pages
428-435
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2025323939
Cited by
398
References
0
FWCI
17.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MECHANICAL DEVICES FOR ARTERIAL OCCLUSION. https://app.cochat.ai/papers/10.2214/ajr.124.3.428
The paper
GIANTURCO, C., ANDERSON, J. H., & WALLACE, S. (1975). MECHANICAL DEVICES FOR ARTERIAL OCCLUSION. American Journal of Roentgenology. https://doi.org/10.2214/ajr.124.3.428

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.