CoChat

CT Angiography of Neonates and Infants: Comparison of Radiation Dose and Image Quality of Target Mode Prospectively ECG-Gated 320-MDCT and Ungated Helical 64-MDCT

Jadhav, Siddharth P., Golriz, Farahnaz, Atweh, Lamya A., Zhang, Wei, Krishnamurthy, Rajesh · 2015 · American Journal of Roentgenology
Cited by 63

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE. The purpose of this study was to evaluate the radiation dose and image quality of target mode prospectively ECG-gated volumetric CT angiography (CTA) performed with a 320-MDCT scanner compared with the radiation dose and image quality of ungated helical CTA performed with a 64-MDCT scanner. MATERIALS AND METHODS. An experience with CTA for cardiovascular indications in neonates and infants 0-6 months old was retrospectively assessed. Radiation doses and quantitative and qualitative image quality scores of 28 CTA examinations performed with a 320-MDCT scanner and volumetric target mode prospective ECG gating plus iterative reconstruction (target mode) were compared with the doses and scores of 28 CTA examinations performed with a 64-MDCT scanner and ungated helical scanning plus filtered back projection reconstruction (ungated mode). All target mode studies were performed during free breathing. Seven ungated CTA examinations (25%) were performed with general endotracheal anesthesia. The findings of 17 preoperative CTA examinations performed in target mode were also compared with surgical reports for evaluation of diagnostic accuracy. RESULTS. All studies performed with target mode technique were diagnostic for the main clinical indication. Effective doses were significantly lower in the target mode group (0.51 ± 0.19 mSv) compared with the ungated mode group (4.8 ± 1.4 mSv) (p < 0.0001). Quantitative analysis revealed no statistically significant difference between the two groups with respect to signal-to-noise ratio (of pulmonary artery and aorta) and contrast-to-noise ratio. Subjective image quality was significantly better with target mode than with ungated mode (p < 0.0001). CONCLUSION. Target mode prospectively ECG-gated volumetric scanning with iterative reconstruction performed with a 320-MDCT scanner has several benefits in cardiovascular imaging of neonates and infants, including low radiation dose, improved image quality, high diagnostic accuracy, and ability to perform free-breathing studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.14.12846

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Jadhav, S. P., Golriz, F., Atweh, L. A., Zhang, W., & Krishnamurthy, R.
Venue
American Journal of Roentgenology
Published
2015-02
Volume
204
Issue
2
Pages
W184-W191
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1968833248
Cited by
63
References
3
FWCI
4.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.