CoChat

Sonography of pyonephrosis: a prospective study

Subramanyam, BR, Raghavendra, BN, Bosniak, MA, Lefleur, RS, Rosen, RJ, Horii, SC · 1983 · American Journal of Roentgenology
Cited by 60

The DOI matches its Crossref record.

Abstract

Sonograms of 73 patients with 92 hydronephrotic kidneys were prospectively reviewed in an attempt to differentiate hydronephrosis from pyonephrosis. Sonographic diagnosis of pyonephrosis was based on the presence of persistent internal echoes, dispersed or dependent, within the dilated pelvocaliceal system. In group 1, consisting of 38 patients without clinical evidence of renal infection, sonography revealed the collecting system distended by urine to be anechoic, for a specificity of 100%. In group 2, consisting of 34 patients with clinical suspicion of renal infection, sonography showed internal echoes within the fluid-filled collecting system in 10 cases; nine of these had pyonephrosis (sensitivity of 90%), and one had hemorrhagic debris without infection (false-positive rate 3%). In the other 24 patients, sonography correctly predicted the absence of infection in all but one case (specificity 97%, false-negative rate 10%). It is concluded that in patients with clinical suspicion of renal infection, sonography has a high degree of accuracy (96%) in the differentiation of pyonephrosis from hydronephrosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.140.5.991

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Subramanyam, B., Raghavendra, B., Bosniak, M., Lefleur, R., Rosen, R., & Horii, S.
Venue
American Journal of Roentgenology
Published
1983-05-01
Volume
140
Issue
5
Pages
991-993
ISSN
  • 0361-803X
  • 1546-3141
Cited by
60
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.