Magnetic resonance imaging with respiratory gating: techniques and advantages
The DOI matches its Crossref record.
Abstract
Respiratory motion is an important problem in magnetic resonance imaging (MRI) of the thorax and upper abdomen. This study assessed several approaches for practical respiratory gating. Methods of acquiring respiratory signals, gated sequencing methods, duration of examination, strategies for reducing examination time, diagnostic quality of gated images, and the influence of respiratory gating on relaxation time measurements were evaluated. Of three different devices for acquiring the respiratory signal, a belt containing a displacement transducer placed around the upper abdomen was found to be most effective and practical. Two pulse-gating modes were implemented, as well as a method for combining cardiac and respiratory gating. Gating methods were tested using phantoms and human volunteers. A spin-conditioned mode of respiratory gating was found to be superior to a more simply implemented triggered mode in which spin-echo (SE) sequencing was interrupted. The time penalty for respiratory gating is technique-dependent. Gated studies with uncontrolled tidal breathing took two to four times longer than nongated studies. When the time between respirations was voluntarily prolonged, gated studies could be only 30%-50% longer than nongated. The standard deviation of relaxation-time measurements for organs that are displaced during respirations was substantially reduced by respiratory gating. Gating acquisition without spin-conditioning gating. Respiratory gating is a practical and useful technique for improving the contrast and spatial resolution of SE images of the upper abdomen and chest. SE images produced with short repetition times were particularly improved by respiratory gating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Motion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Feng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Wang, Y., Riederer, S. J., & Ehman, R. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330517 · Cited by 491
Self-citationA study of the motion and deformation of the heart due to respiration
McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804427 · Cited by 281
Advances in 4D Medical Imaging and 4D Radiation Therapy
Li, G., Citrin, D., Camphausen, K., Mueller, B., Burman, C., Mychalczak, B., Miller, R. W., & Song, Y. (2008) · Technology in Cancer Research & Treatment · doi:10.1177/153303460800700109 · Cited by 177
Motion in Cardiovascular MR Imaging
Scott, A. D., Keegan, J., & Firmin, D. N. (2009) · Radiology · doi:10.1148/radiol.2502071998 · Cited by 175
Metadata
- Authors
- Ehman, R., McNamara, M., Pallack, M., Hricak, H., & Higgins, C.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1984-12-01
- Volume
- 143
- Issue
- 6
- Pages
- 1175-1182
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2160218787
- Cited by
- 299
- References
- 0
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.