Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 259

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of renal transplant rejection by duplex Doppler examination: value of the resistive index

Rifkin, MD, Needleman, L, Pasto, ME, Kurtz, AB, Foy, PM, McGlynn, E, Canino, C, Baltarowich, OH, Pennell, RG, Goldberg, BB · 1987 · American Journal of Roentgenology

Abstract

The increasing use and availability of renal transplantation has resulted in a demand for noninvasive methods to study possible complications. One of the most serious adverse reactions is acute rejection, a possibly reversible cause of transplant failure if treated promptly. Differentiation from other causes of acute renal failure frequently is difficult, and the lack of specificity in many imaging studies has been troublesome. Eighty-one patients with renal transplants, including 41 with acute rejection, were examined. Duplex Doppler examination of the intrarenal arteries and a simplified formula, the resistive index ([peak systolic frequency shift--lowest diastolic frequency shift]/[peak systolic frequency shift]), were used to diagnose rejection. With a resistive index greater than 0.90, a 100% positive predictive value was obtained for the diagnosis of acute rejection. A value less than 0.70 was unlikely to be rejection (negative predictive value, 94%). This approach uses a simple analysis of the waveform. Use of a duplex Doppler examination and the formula described here appears to be an accurate method for the detection of acute rejection and for the differentiation of acute rejection from the various other causes of acute renal failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.148.4.759

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 259

Metadata

Authors
Rifkin, M., Needleman, L., Pasto, M., Kurtz, A., Foy, P., McGlynn, E., Canino, C., Baltarowich, O., Pennell, R., & Goldberg, B.
Venue
American Journal of Roentgenology
Published
1987-04-01
Volume
148
Issue
4
Pages
759-762
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1991257713
Cited by
259
References
1
FWCI
9.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of renal transplant rejection by duplex Doppler examination: value of the resistive index. https://app.cochat.ai/papers/10.2214/ajr.148.4.759
The paper
Rifkin, M., Needleman, L., Pasto, M., Kurtz, A., Foy, P., McGlynn, E., Canino, C., Baltarowich, O., Pennell, R., & Goldberg, B. (1987). Evaluation of renal transplant rejection by duplex Doppler examination: value of the resistive index. American Journal of Roentgenology. https://doi.org/10.2214/ajr.148.4.759

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.