Fatty infiltration of the liver: quantification with phase-contrast MR imaging at 1.5 T vs biopsy.

Levenson, H, Greensite, F, Hoefs, J, Friloux, L, Applegate, G, Silva, E, Kanel, G, Buxton, R·1991·American Journal of Roentgenology

Abstract

Quantification of hepatic fat content by application of MR phase-contrast imaging (Dixon method) at 1.5 T was compared with results of biopsy in 16 patients with a variety of liver abnormalities. Motion artifact was suppressed by employing six or eight averages of short TR in-phase (echo offset, 0 msec), out-of-phase (echo offset, 1.1 msec), and in-phase (echo offset, 2.2 msec) spin-echo pulse sequences. The 360 degree out-of-phase sequence was used to assess the impact of T2* decay on this method of estimating fat fraction. A standard two-echo long TR sequence also was obtained in all patients. Histologic preparations from the biopsy specimens were examined by a pathologist who had no knowledge of the MR results and were graded according to overall visual assessment as belonging to one of four categories of fat fraction. Results of the MR-calculated apparent fat fraction were compared directly with biopsy category and were also placed in MR fat fraction categories, allowing estimation of the statistical correlation between the biopsy and MR grading systems. Eight of eight patients with biopsy categories indicating a fat fraction of less than 0.25 were computed by MR to have a fat fraction of less than 0.1. Seven of eight patients with biopsy categories indicating a fat fraction of greater than 0.25 were computed by MR to have a fat fraction of at least 0.24. The MR-calculated apparent fat fraction category correlated significantly with the histologic biopsy category (r = .86, p less than .01). When compared with the in-phase image, decreased signal from liver was visually apparent on the 180 degree out-of-phase images in all cases in which the fat fraction was at least 0.24, but there was no indication of fatty liver on the standard T1- or T2-weighted images. Calculated T2 also showed no correlation with degree of fatty deposition. Correction for T2* decay by using the 360 degree out-of-phase acquisition in addition to the standard 0 degree and 180 degree out-of-phase images had little effect on fat fraction computation. Phase-contrast MR is a promising noninvasive method for quantitative assessment of fatty deposition in the liver.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.156.2.1898804

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Levenson, H., Greensite, F., Hoefs, J., Friloux, L., Applegate, G., Silva, E., Kanel, G., & Buxton, R.
Venue
American Journal of Roentgenology
Published
1991-02
Volume
156
Issue
2
Pages
307-312
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2051150261
Cited by
171
References
0
FWCI
3.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fatty infiltration of the liver: quantification with phase-contrast MR imaging at 1.5 T vs biopsy. https://app.cochat.ai/papers/10.2214/ajr.156.2.1898804
The paper
Levenson, H., Greensite, F., Hoefs, J., Friloux, L., Applegate, G., Silva, E., Kanel, G., & Buxton, R. (1991). Fatty infiltration of the liver: quantification with phase-contrast MR imaging at 1.5 T vs biopsy. American Journal of Roentgenology. https://doi.org/10.2214/ajr.156.2.1898804

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.