The DOI matches its Crossref record.
Value of sonography in determining the nature of pleural effusion: analysis of 320 cases.
Abstract
To assess the value of sonography in determining the nature of pleural effusions, we prospectively analyzed the sonographic findings in 320 patients with pleural effusion of various causes (224 with exudates and 96 with transudates). The nature of the effusions was established on the basis of chemical, bacteriologic, and cytologic examination of pleural fluid; pleural biopsy; and clinical follow-up. All patients had high-frequency, real-time sonography performed by one of three sonographers who had no clinical information concerning the patients. The sonographer evaluated the images for internal echogenicity of the effusion, thickness of the pleura, and associated parenchymal lesions of the lung. The images were also printed out and interpreted a second time by the other two sonographers to reach a consensus. Our results showed that the two types of effusions could be distinguished on the basis of sonographic findings. Transudates were anechoic, whereas an anechoic effusion could be either a transudate or an exudate. Pleural effusions with complex septated, complex nonseptated, or homogeneously echogenic patterns were always exudates (p less than .01). Sonographic findings of thickened pleura and associated parenchymal lesions in the lung also were indicative of an exudate (p less than .01). Homogenous echogenic effusions were due to hemorrhagic effusion or empyema. Sonographic evidence of a pleural nodule was a specific finding in patients with a malignant effusion. We conclude that sonography is useful in determining the nature of pleural effusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Establishing the Diagnosis of Lung Cancer
Rivera, M. P., Mehta, A. C., & Wahidi, M. M. (2013) · Chest · doi:10.1378/chest.12-2353 · Cited by 1,089
Hooper, C., Lee, Y. C. G., Maskell, N., & on behalf of the BTS Pleural Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.136978 · Cited by 824
Pleural procedures and thoracic ultrasound: British Thoracic Society pleural disease guideline 2010
Havelock, T., Teoh, R., Laws, D., Gleeson, F., & on behalf of the BTS Pleural Disease Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.137026 · Cited by 794
Lung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 711
Metadata
- Authors
- Yang, P. C., Luh, K. T., Chang, D. B., Wu, H. D., Yu, C. J., & Kuo, S. H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1992-07
- Volume
- 159
- Issue
- 1
- Pages
- 29-33
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1972440498
- Cited by
- 530
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Value of sonography in determining the nature of pleural effusion: analysis of 320 cases. https://app.cochat.ai/papers/10.2214/ajr.159.1.1609716
- The paper
- Yang, P. C., Luh, K. T., Chang, D. B., Wu, H. D., Yu, C. J., & Kuo, S. H. (1992). Value of sonography in determining the nature of pleural effusion: analysis of 320 cases. American Journal of Roentgenology. https://doi.org/10.2214/ajr.159.1.1609716
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.