CoChat

Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature.

Austin, J H, Cohen, M B · 1993 · American Journal of Roentgenology
Cited by 184

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Percutaneous fine-needle aspiration biopsy is an accepted procedure for diagnosing intrathoracic malignant disease. The value of having a cytopathologist present during the procedure was studied with respect to the number of needle passes, the accuracy of the procedure, and complications. A metaanalysis was performed on the combined results of the present and previous series. SUBJECTS AND METHODS: We analyzed data from 55 adult patients who underwent percutaneous CT-guided fine-needle (22-gauge) aspiration biopsy of the lung for a lesion that either the biopsy or another subsequent invasive procedure showed to be nonlymphomatous and malignant. A cytopathologist was present for the first 25 procedures and not present for the next 30 procedures. When present, the cytopathologist stained the aspirated material with toluidine blue and gave an immediate opinion on the diagnostic adequacy of the specimen based on microscopic evaluation. If appropriate, the radiologist obtained additional biopsy specimens. When a cytopathologist was not present, the radiologist assessed the adequacy of the specimen by gross examination. A metaanalysis was performed of 211 cases from the present study and two previous series with respect to the effect of the presence of a cytopathologist on the diagnostic accuracy of the procedure. RESULTS: Biopsy specimens showed cancer in 25 (100%) of 25 patients when obtained while the cytopathologist was present, and in 24 (80%) of 30 patients when obtained while the cytopathologist was absent (p < .05, Fisher exact test). No significant differences in the number of needle passes performed or in the frequency of pneumothorax when aerated lung was traversed were noted between the two groups. Although two previous studies showed nonsignificant trends toward increased accuracy of thoracic fine-needle aspiration when a cytopathologist participated in the procedure, metaanalysis revealed significantly increased accuracy when a cytopathologist was present (p < .02, Mantel-Haenszel chi 2-test). CONCLUSION: An accurate diagnosis from fine-needle aspiration biopsy of intrathoracic cancer was more likely when a cytopathologist was present than when not present during the procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.160.1.8416620

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Austin, J. H., & Cohen, M. B.
Venue
American Journal of Roentgenology
Published
1993-01
Volume
160
Issue
1
Pages
175-177
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2056210486
Cited by
184
References
5
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.