Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record.

Severity of articular cartilage abnormality in patients with osteoarthritis: evaluation with fast spin-echo MR vs arthroscopy.

Broderick, L S, Turner, D A, Renfrew, D L, Schnitzer, T J, Huff, J P, Harris, C · 1994 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to assess the accuracy of fast spin-echo MR imaging for depicting the severity of articular cartilage abnormalities in patients with osteoarthritis. SUBJECTS AND METHODS: Twenty-three subjects (10 volunteers less than 35 years old and 13 patients with proved, symptomatic, idiopathic osteoarthritis of the knee of 6 months' to 10 years' clinical duration) underwent fast spin-echo MR imaging of the knee. Two observers graded each articular surface using a five-category scale that took into account abnormalities in the signal intensity of cartilage as well as thickness and contour. The 13 patients also underwent arthroscopic evaluation (as part of a separate protocol) in which cartilage abnormalities were graded by using a similar five-category grading scale, without the graders knowing the results of MR imaging. Articular cartilage was assumed to be normal in the volunteers. RESULTS: One hundred thirty-seven joint surfaces were graded; one surface was obscured by artifact and was excluded. The Spearman rank linear correlation between arthroscopic and MR grading was highly significant (p < .002) for each of the six articular regions evaluated. The MR and arthroscopic grades were the same in 93 (68%) of 137 joint surfaces, they were the same or differed by one grade in 123 surfaces (90%), and they were the same or differed by one or two grades in 129 surfaces (94%). CONCLUSION: Our results suggest that fat-presaturated fast spin-echo MR imaging depicts the severity of articular cartilage abnormalities in osteoarthritis with reasonable accuracy, as compared with arthroscopic evaluation as the standard of reference.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.162.1.8273700

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Broderick, L. S., Turner, D. A., Renfrew, D. L., Schnitzer, T. J., Huff, J. P., & Harris, C.
Venue
American Journal of Roentgenology
Published
1994-01
Volume
162
Issue
1
Pages
99-103
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1969461243
Cited by
164
References
0
FWCI
5.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Severity of articular cartilage abnormality in patients with osteoarthritis: evaluation with fast spin-echo MR vs arthroscopy. https://app.cochat.ai/papers/10.2214/ajr.162.1.8273700
The paper
Broderick, L. S., Turner, D. A., Renfrew, D. L., Schnitzer, T. J., Huff, J. P., & Harris, C. (1994). Severity of articular cartilage abnormality in patients with osteoarthritis: evaluation with fast spin-echo MR vs arthroscopy. American Journal of Roentgenology. https://doi.org/10.2214/ajr.162.1.8273700

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.