Comparison of upright inspiratory and expiratory chest radiographs for detecting pneumothoraces.
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Expiratory films are regarded as being superior to inspiratory films for pneumothorax detection, yet this has not been proved. In the current study, we compared inspiratory versus expiratory chest radiographs for pneumothorax detection. MATERIALS AND METHODS: Eighty-five paired inspiratory and expiratory radiographs with pneumothoraces and 93 pairs without pneumothoraces were randomly arranged and reviewed independently by three radiologists. A score of 1-5 was assigned for each hemithorax (5 = definite pneumothorax, 1 = definitely no pneumothorax). Results were compared for inspiration and expiration using receiver operating characteristic (ROC) analysis. RESULTS: The average area under the ROC curves for all readers was .973 for inspiration and .972 for expiration (nonsignificant). McNemar's test and an alpha level of .05 also yielded no significant difference in sensitivity and specificity. Four of the 85 cases were scored as definite pneumothorax on inspiration and as definitely not on expiration by all readers, and three of the 85 cases were scored as definite pneumothorax on expiration and as definitely not on inspiration. CONCLUSION: Inspiratory and expiratory upright films are equally sensitive for pneumothorax detection. Given the limitations of expiratory films, inspiratory films are recommended as the initial examination of choice for pneumothorax detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of spontaneous pneumothorax: British Thoracic Society pleural disease guideline 2010
MacDuff, A., Arnold, A., Harvey, J., & on behalf of the BTS Pleural Disease Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.136986 · Cited by 1,481
“They are generally less sensitive than erect PA x-rays for the diagnosis of pneumothorax 37 38 and have been superseded by ultrasound or CT imaging for patients who cannot assume the erect posture.”
BackgroundTaylor, A. G., Mielke, C., & Mongan, J. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002697 · Cited by 212
Common Errors and Pitfalls in Interpretation of the Adult Chest Radiograph
Kanne, J. P., Thoongsuwan, N., & Stern, E. J. (2005) · Clinical Pulmonary Medicine · doi:10.1097/01.cpm.0000156704.33941.e2 · Cited by 17
“The upright inspiratory frontal chest radiograph is extremely sensitive for detecting pneumothorax and, when of good quality, is just as good as an expiratory radiograph.(26) In the upright position, the radiographic findings of pneumothorax include separation of the visceral and parietal pleura near the apex with a v…”
Background
Metadata
- Authors
- Seow, A., Kazerooni, E. A., Pernicano, P. G., & Neary, M.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1996-02
- Volume
- 166
- Issue
- 2
- Pages
- 313-316
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2123194985
- Cited by
- 82
- References
- 0
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of upright inspiratory and expiratory chest radiographs for detecting pneumothoraces. https://app.cochat.ai/papers/10.2214/ajr.166.2.8553937
- The paper
- Seow, A., Kazerooni, E. A., Pernicano, P. G., & Neary, M. (1996). Comparison of upright inspiratory and expiratory chest radiographs for detecting pneumothoraces. American Journal of Roentgenology. https://doi.org/10.2214/ajr.166.2.8553937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.