Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record.

Early detection of pneumonia in febrile neutropenic patients: use of thin-section CT.

Heussel, C P, Kauczor, H U, Heussel, G, Fischer, B, Mildenberger, P, Thelen, M·1997·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to evaluate the usefulness of thin-section CT for early detection of pneumonia in neutropenic patients with an unknown site of infection and normal or nonspecific findings on chest radiographs. SUBJECTS AND METHODS: Eighty-seven patients with febrile neutropenia that persisted for more than 2 days despite empiric antibiotic treatment underwent 146 prospective examinations. If findings on chest radiographs were normal (n = 126) or nonspecific (n = 20), thin-section CT (1-mm collimation, 10-mm increment) was done. If thin-section CT scans showed opacities, bronchoalveolar lavage was recommended. RESULTS: Findings on chest radiographs were nonspecific for pneumonia in 20 (14%) of 146 cases, and CT findings in those cases were suggestive of pneumonia. Microorganisms were detected in 11 of those 20 cases. Seven of the 11 cases were not optimally treated before CT diagnosis, the other four were sufficiently treated. Findings on chest radiographs and thin-section CT scans were normal in 56 (38%) of 146 cases. In 70 (48%) of 146 cases, findings on chest radiographs were normal, whereas findings on thin-section CT scans were suggestive of pneumonia. Microorganisms were detected in 30 of the 70 cases. Nineteen of 30 cases were not optimally treated before CT, whereas the other 11 cases were sufficiently treated before CT. In 22 (31%) of these 70 cases, an opacity was observed on the chest radiograph during the 7 days after the CT study. Only three (5%) of 56 pneumonias occurred during the first 7 days after thin-section CT studies with normal findings (p < .005). Additional risk factors for pneumonia occurring later that were detectable on chest radiographs were poorly defined nodules (p < .05), consolidation (p < .05), and younger age (p < .05). CONCLUSION: Thin-section CT scans show findings suggestive of pneumonia about 5 days earlier than chest radiographs show suggestive findings. When thin-section CT scans show findings suggestive of pneumonia, the probability of pneumonia being detected on chest radiographs during the 7-day follow-up is 31%, whereas the probability is only 5% when the findings on the prior thin-section CT scan were normal (p < .005). All neutropenic patients with fever of unknown origin and normal findings on chest radiographs should be examined with thin-section CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.169.5.9353456

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Heussel, C. P., Kauczor, H. U., Heussel, G., Fischer, B., Mildenberger, P., & Thelen, M.
Venue
American Journal of Roentgenology
Published
1997-11
Volume
169
Issue
5
Pages
1347-1353
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2115687262
Cited by
192
References
0
FWCI
1.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early detection of pneumonia in febrile neutropenic patients: use of thin-section CT. https://app.cochat.ai/papers/10.2214/ajr.169.5.9353456
The paper
Heussel, C. P., Kauczor, H. U., Heussel, G., Fischer, B., Mildenberger, P., & Thelen, M. (1997). Early detection of pneumonia in febrile neutropenic patients: use of thin-section CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.169.5.9353456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.